• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2212.2 Continuity and Ties

NYC Building Code 2014 > 22 Steel > 2212 Structural Integrity Requirements > 2212.2 Continuity and Ties
JUMP TO FULL CODE CHAPTER
The following requirements shall be met:
  1. All bolted connections shall have at least two bolts.
  2. Bolted connections of all columns, beams, braces and other structural elements that are part of the lateral load resisting system shall be designed as bearing-type connections with pretensioned bolts or as slip critical connections.
  3. End connections of all beams and girders shall have a minimum available tensile strength equal to the larger of the available vertical shear strength of the connections at either end, but not less than 10 kips (45 kN). For the design of the connections, the shear force and the axial tensile force need not be considered to act simultaneously. For the purpose of this provision, a connection shall be considered compliant if it meets the following requirements:
    1. For single-plate shear connections, the available tensile strength shall be determined only for the limit state of bolt bearing on the plate and beam web.
    2. For single angle and double angle shear connections, the available tensile strength shall be determined for the limit states of bolt bearing on the angles and beam web and for tension yielding on the gross area of the angles.
    3. All other connections shall be designed for the required tension force noted above in accordance with the provisions of AISC 360, or AISC-HSS.
  4. For the purpose of satisfying these integrity provisions only, bearing bolts in connections with short-slotted holes parallel to the direction of the tension force and inelastic deformation are permitted. Elements and their connections that brace compression members shall have a minimum available tensile strength equal to at least 2 percent of the required compressive strength of the member being braced, but not less than 10 kips (45 kN). For design of these bracing connections, the shear force and the tensile force need not be considered to act simultaneously. Where more than one element braces a compression member at a point in one direction, all elements and connections shall have a minimum available tensile strength equal to at least 1 percent of the required compressive strength of the member being braced but not less than 10 kips (45 kN).

2212.2.1 Vertical Ties

Column splices shall have an available tensile strength at least equal to the largest design gravity load reaction applied to the column at any floor level located within four floors below the splice.

Related Code Sections


1615.2 Structural Design, Continuity and Ties
All structural elements shall have a minimum degree of continuity and shall be tied together horizontally and vertically as specified in Chapters 19 ...
NYC Building Code 2014 > 16 Structural Design > 1615 Structural Integrity — Prescriptive Requirements > 1615.2 Continuity and Ties
1625.2 Structural Design, Continuity and Ties
All structural elements shall have a minimum degree of continuity and shall be tied together horizontally and vertically as specified ...
NYC Building Code 2008 > 16 Structural Design > 1625 Structural Integrity — Prescriptive Requirements > 1625.2 Continuity and Ties
1916.2 Concrete, Continuity and Ties
At each floor and roof level, reinforcement forming a continuous peripheral tie shall be provided. Peripheral ties shall be located within ...
NYC Building Code 2014 > 19 Concrete > 1916 Structural Integrity Requirements > 1916.2 Continuity and Ties
1917.2 Concrete, Continuity and Ties
At each floor and roof level, reinforcement forming a continuous peripheral tie shall be provided. Peripheral ties shall be located ...
NYC Building Code 2008 > 19 Concrete > 1917 Structural Integrity Requirements > 1917.2 Continuity and Ties
2114.2 Masonry, Continuity and Ties
Load-bearing masonry structures shall be reinforced to obtain a continuous system of vertical and horizontal ties. Continuity of all ties shall ...
NYC Building Code 2008 > 21 Masonry > 2114 Structural Integrity Requirements > 2114.2 Continuity and Ties
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE