• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.153(g) Containers and Regulating Equipment Installed Outside of Buildings or Structures

OSHA 1926 Construction > F Fire Protection and Prevention > 1926.153 Liquefied Petroleum Gas (LP-gas) > 1926.153(g) Containers and Regulating Equipment Installed Outside of Buildings or Structures
JUMP TO FULL CODE CHAPTER
Containers shall be upright upon firm foundations or otherwise firmly secured. The possible effect on the outlet piping of settling shall be guarded against by a flexible connection or special fitting.

Related Code Sections


1926.153(g) Fire Protection and Prevention, Containers and Regulating Equipment Installed Outside of Buildings or Structures
Containers shall be upright upon firm foundations or otherwise firmly secured. The possible effect on the outlet piping of settling shall be guarded ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.153 Liquefied Petroleum Gas (LP-gas) > 1926.153(g) Containers and Regulating Equipment Installed Outside of Buildings or Structures
1926.153(h)(9) Fire Protection and Prevention,
Container valves, connectors, regulators, manifolds, piping, and tubing shall not be used as structural supports for heaters ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.153 Liquefied Petroleum Gas (LP-gas) > 1926.153(h) Containers and Equipment Used Inside of Buildings or Structures > 1926.153(h)(9)
1926.153(h)(10) Fire Protection and Prevention,
Containers, regulating equipment, manifolds, pipe, tubing, and hose shall be located to minimize exposure to high temperatures or physical damage ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.153 Liquefied Petroleum Gas (LP-gas) > 1926.153(h) Containers and Equipment Used Inside of Buildings or Structures > 1926.153(h)(10)
1926.153(k) Fire Protection and Prevention, Storage Outside of Buildings
Storage outside of buildings, for containers awaiting use, shall be located from the nearest building or group of buildings, in accordance ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.153 Liquefied Petroleum Gas (LP-gas) > 1926.153(k) Storage Outside of Buildings
1926.408(c)(3)(i) Electrical, Outside of Buildings
Receiving distribution lead-in or aerial-drop cables attached to buildings and lead-in conductors to radio transmitters shall be so installed ...
OSHA 1926 Construction > K Electrical > 1926.408 Special Systems > 1926.408(c) Communications Systems > 1926.408(c)(3) Conductor Location > 1926.408(c)(3)(i) Outside of Buildings
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE