1906.4 Construction Joints
JUMP TO FULL CODE CHAPTER
Construction joints, including their location, shall comply with the provisions of ACI 318, Section 6.4. Construction joints including their location shall be approved by the registered design professional of record prior to installation.
Related Code Sections
1905.10.7 Concrete, Construction Joints
When construction joints are required, they shall be made in accordance with Section 1906.8 ...
NYC Building Code 2008 > 19 Concrete > 1905 Concrete Quality, Mixing and Placing > 1905.10 Depositing > 1905.10.7 Construction Joints
1905.10.7 Concrete, Construction Joints
When construction joints are required, they shall be made in accordance with Section 1906.4 ...
NYC Building Code 2014 > 19 Concrete > 1905 Concrete Quality, Mixing and Placing > 1905.10 Depositing > 1905.10.7 Construction Joints
1906.4 Concrete, Construction Joints
Construction joints, including their location, shall comply with the provisions of ACI 318, Section 6.4. Construction joints including their location ...
NYC Building Code 2014 > 19 Concrete > 1906 Formwork, Embedded Pipes and Construction Joints > 1906.4 Construction Joints
1906.8 Concrete, Construction Joints
Construction joints shall comply with the provisions of Sections 1906.8.1 through 1906.8.6 ...
NYC Building Code 2008 > 19 Concrete > 1906 Formwork, Embedded Pipes and Construction Joints > 1906.8 Construction Joints
1906.8.4 Concrete, Location in Slabs, Beams and Girders
Construction joints in floors shall be located within the middle third of spans of slabs, beams and girders. Joints in girders shall be offset ...
NYC Building Code 2008 > 19 Concrete > 1906 Formwork, Embedded Pipes and Construction Joints > 1906.8 Construction Joints > 1906.8.4 Location in Slabs, Beams and Girders