// CODE SNIPPET
R606.12.2.3.2 Connections to Masonry Columns
Go To Full Code Chapter
Connectors shall be provided to transfer forces between masonry columns and horizontal elements in accordance with the requirements of Section 4.1.4 of TMS 402. Where anchor bolts are used to connect horizontal elements to the tops of columns, the bolts shall be placed within lateral ties. Lateral ties shall enclose both the vertical bars in the column and the anchor bolts. There shall be not less than two No. 4 lateral ties provided in the top 5 inches (127 mm) of the column.
Upcodes Diagrams
Related Code Sections
R606.12.2.3.2 Wall Construction, Connections to Masonry Columns
Connectors shall be provided to transfer forces between masonry columns and horizontal elements in accordance with the requirements of Section 4.1.4 ...
7.2.9 Masonry Chimneys, Notice of Usage
Where a Type B gas vent, special gas vent, pellet vent, or other material not suitable for use under Columns I and II of Table 5.2.2.1 is used ...
7.2.9 Masonry Chimneys, Notice of Usage
Where a Type B gas vent, special gas vent, pellet vent, or other material not suitable for use under Columns I and II of Table 5.2.2.1 is used ...
2304.11.1 Wood, Details of Heavy Timber Structural Members
Columns shall be continuous or superimposed throughout all stories and connected in an approved manner. Girders and beams at column connections shall ...
2304.11.1 Wood, Details of Heavy Timber Structural Members
Columns shall be continuous or superimposed throughout all stories and connected in an approved manner. Girders and beams at column connections shall ...