• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

801.5 Connections From Water Distribution System

California Plumbing Code 2016 > 8 Indirect Wastes > 801.0 General > 801.5 Connections From Water Distribution System
JUMP TO FULL CODE CHAPTER
Indirect waste connections shall be provided for drains, overflows, or relief pipes from potable water pressure tanks, water heaters, boilers, and similar equipment that is connected to the potable water distribution system. Such indirect waste connections shall be made by means of a water-distribution air gap constructed in accordance with Table 603.3.1.

Related Code Sections


801.5 Indirect Wastes, Connections From Water Distribution System
, and similar equipment that is connected to the potable water distribution system. Such indirect waste connections shall be made using a water-distribution ...
California Plumbing Code 2019 > 8 Indirect Wastes > 801.0 General > 801.5 Connections From Water Distribution System
801.5 Indirect Wastes, Connections From Water Distribution System
, and similar equipment that is connected to the potable water distribution system. Such indirect waste connections shall be made by means of a water ...
California Plumbing Code 2016 > 8 Indirect Wastes > 801.0 General > 801.5 Connections From Water Distribution System
602.0 Water Supply and Distribution, Unlawful Connections
water supplied by a public or private building supply system, and pipes, conduits, or fixtures containing or carrying water from any other source ...
California Plumbing Code 2016 > 6 Water Supply and Distribution > 602.0 Unlawful Connections
602.0 Water Supply and Distribution, Unlawful Connections
water supplied by a public or private building supply system, and pipes, conduits, or fixtures containing or carrying water from any other source ...
California Plumbing Code 2019 > 6 Water Supply and Distribution > 602.0 Unlawful Connections
1602.11.2.2 Nonpotable Rainwater Catchment Systems, Cross-Connection Test
, shall be tested and inspected for flow. Flow from a rainwater catchment water system outlet shall indicate a cross-connection. No flow from a potable ...
California Plumbing Code 2016 > 16 Nonpotable Rainwater Catchment Systems > 1602.0 Nonpotable Rainwater Catchment Systems > 1602.11 Inspection and Testing > 1602.11.2 Cross-Connection Inspection and Testing > 1602.11.2.2 Cross-Connection Test
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE