611.9.2 Connections Between Concrete Walls and Lightframed Floor Systems
JUMP TO FULL CODE CHAPTER
Connections between concrete walls and light-framed floor systems shall be in accordance with one of the following:
- For floor systems of wood frame construction, the provisions of Section 611.9.1 and the prescriptive details of Figures 611.9(1) through 611.9(4), where permitted by the tables accompanying those figures. Portions of connections of wood-framed floor systems not noted in the figures shall be in accordance with Section 502, or AF&PA/WFCM, if applicable.
- For floor systems of cold-formed steel construction, the provisions of Section 611.9.1 and the prescriptive details of Figures 611.9(5) through 611.9(8), where permitted by the tables accompanying those figures. Portions of connections of cold-formed-steel framed floor systems not noted in the figures shall be in accordance with Section 505, or AISI S230, if applicable.
- Proprietary connectors selected to resist loads and load combinations in accordance with Appendix A (ASD) or Appendix B (LRFD) of PCA 100.
- An engineered design using loads and load combinations in accordance with Appendix A (ASD) or Appendix B (LRFD) of PCA 100.
- An engineered design using loads and material design provisions in accordance with this code, or in accordance with ASCE 7, ACI 318, and AF&PA/NDS for wood frame construction or AISI S100 for coldformed steel frame construction.
Related Code Sections
611.9.2 Wall Construction, Connections Between Concrete Walls and Lightframed Floor Systems
Connections between concrete walls and light-framed floor systems shall be in accordance with one of the following: For floor systems of wood ...
Ohio Residential Code 2013 > 6 Wall Construction > 611 Exterior Concrete Wall Construction > 611.9 Requirements for Connections—General > 611.9.2 Connections Between Concrete Walls and Lightframed Floor Systems
16.2.5 Connections Between Members, Integrity Tie Requirements for Precast Concrete Bearing Wall Structures Three Stories or More in Height
shall be provided over interior wall supports and between the floor or roof system and exterior walls. (c) Longitudinal and transverse integrity ...
Building Code Requirements for Structural Concrete of Ohio > 16 Connections Between Members > 16.2 Connections of Precast Members > 16.2.5 Integrity Tie Requirements for Precast Concrete Bearing Wall Structures Three Stories or More in Height
4.12.1 Structural System Requirements, Precast Concrete Systems
floor or wall system, (a) and (b) shall be satisfied: (a) In-plane load paths shall be continuous through both connections and members. (b) Where ...
Building Code Requirements for Structural Concrete of Ohio > 4 Structural System Requirements > 4.12 Requirements for Specific Types of Construction > 4.12.1 Precast Concrete Systems