AS105.5 Connection of Light-Framed Walls to Strawbale Walls
Go To Full Code Chapter
Light-framed walls perpendicular to, or at an angle to a straw bale wall assembly, shall be fastened to the bottom and top wood members of the strawbale wall in accordance with requirements for wood or cold-formed steel light-framed walls in this code, or the abutting stud shall be connected to alternating straw bale courses with a 1/2-inch diameter (12.7 mm) steel, 3/4-inch-diameter (19.1 mm) wood or 5/8-inch-diameter (15.9 mm) bamboo dowel, with not less than 8-inch (203 mm) penetration.
Related Code Sections
AS105.5 Strawbale Construction, Connection of Light-Frame Walls to Strawbale Walls
of the strawbale wall in accordance with requirements for wood or cold-formed steel light-frame walls in this code, or the abutting stud shall be connected ...
AS105.5 Strawbale Construction, Connection of Light-Framed Walls to Strawbale Walls
of the strawbale wall in accordance with requirements for wood or cold-formed steel light-framed walls in this code, or the abutting stud shall be connected ...
AS105.5 Strawbale Construction, Connection of Light-Framed Walls to Strawbale Walls
of the strawbale wall in accordance with requirements for wood or cold-formed steel light-framed walls in this code, or the abutting stud shall be connected ...
AS106.15 Strawbale Construction, Post-and-Beam With Strawbale Infill
Post-and-beam with strawbale infill systems shall be in accordance with Figure AS105.1(4) and Items 1 through 6, or be of an approved engineered ...
AS106.15 Strawbale Construction, Post-and-Beam With Strawbale Infill
Post-and-beam with strawbale infill systems shall be in accordance with Figure AS105.1(4) and Items 1 through 7, or be of an approved engineered ...