• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

914.4.1 Connection and Installation

Plumbing Code 2018 of Kansas > 9 Vents > 914 Circuit Venting > 914.4 Relief Vent > 914.4.1 Connection and Installation
JUMP TO FULL CODE CHAPTER
The relief vent shall connect to the horizontal branch drain between the stack and the most downstream fixture drain of the circuit vent. The relief vent shall be installed in accordance with Section 905.

Related Code Sections


914.4.1 Vents, Connection and Installation
The relief vent shall connect to the horizontal branch drain between the stack and the most downstream fixture drain of the circuit vent. The ...
Plumbing Code 2018 of Kansas > 9 Vents > 914 Circuit Venting > 914.4 Relief Vent > 914.4.1 Connection and Installation
(1) Equipment for General Use, Cord-Connected Installation
A luminaire or a listed assembly in compliance with any of the conditions in (a) through (c) shall be permitted to be cord connected provided ...
National Electrical Code 2017 of Kansas > 4 Equipment for General Use > 410 Luminaires, Lampholders, and Lamps > 410.62 Cord-Connected Lampholders and Luminaires > (C) Electric-Discharge and LED Luminaires > (1) Cord-Connected Installation
411.1.3.1 Gas Piping Installations, Maximum Length
connector shall be used for each appliance . Exception: Rigid metallic piping used to connect an appliance to the piping system shall ...
Fuel Gas Code 2018 of Kansas > 4 Gas Piping Installations > 411 (IFGC) Appliance and Manufactured Home Connections > 411.1 Connecting Appliances > 411.1.3 Connector Installation > 411.1.3.1 Maximum Length
1203.3.1 Hydronic Piping, Brazed Joints
Joint surfaces shall be cleaned. An approved flux shall be applied where required. The joint shall be brazed with a filler metal conforming to AWS ...
Mechanical Code 2018 of Kansas > 12 Hydronic Piping > 1203 Joints and Connections > 1203.3 Joint Preparation and Installation > 1203.3.1 Brazed Joints
1203.3.4 Hydronic Piping, Solvent-Cemented Joints
connections, a primer is not required where all of the following conditions apply: The solvent cement used is third-party certified as conforming ...
Mechanical Code 2018 of Kansas > 12 Hydronic Piping > 1203 Joints and Connections > 1203.3 Joint Preparation and Installation > 1203.3.4 Solvent-Cemented Joints
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING