• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E3904.6 Conduit and Tubing Fill

2014 FBC - Residential, 5th edition > 39 Power and Lighting Distribution > E3904 General Installation Requirements > E3904.6 Conduit and Tubing Fill
JUMP TO FULL CODE CHAPTER

The maximum number of conductors installed in conduit or tubing shall be in accordance with Tables E3904.6(1) through E3904.6(10).

TABLE E3904.6(1)
MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL METALLIC TUBING (EMT)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
4
3
2
1
1
1
1
1
0
0
0
0
0
7
6
5
2
1
1
1
1
1
1
1
0
0
11
9
8
4
3
2
1
1
1
1
1
1
1
20
17
13
7
5
4
4
3
1
1
1
1
1
27
23
18
9
8
6
5
4
3
2
2
1
1
46
38
30
16
13
10
9
7
5
4
4
3
3
TW14
12
10
8
8
6
5
2
15
11
8
5
25
19
14
8
43
33
24
13
58
45
33
18
96
74
55
30
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
6
4
3
1
10
8
6
4
16
13
10
6
28
23
18
10
39
31
24
14
64
51
40
24
RHWa, RHW-2a, TW, THW,
THHW, THW-2
6
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
1
0
0
0
0
3
1
1
1
1
1
1
1
0
4
3
3
2
1
1
1
1
1
8
6
5
4
3
2
1
1
1
11
8
7
6
4
3
3
2
1
18
13
12
10
7
6
5
4
3
THHN, THWN, THWN-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
12
9
5
3
2
1
1
1
1
1
0
0
0
22
16
10
6
4
2
1
1
1
1
1
1
1
35
26
16
9
7
4
3
3
1
1
1
1
1
61
45
28
16
12
7
6
5
4
3
2
1
1
84
61
38
22
16
10
8
7
5
4
3
3
2
138
101
63
36
26
16
13
11
8
7
6
5
4
XHHW, XHHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
8
6
5
2
1
1
1
1
1
1
0
0
0
15
11
8
5
3
2
1
1
1
1
1
1
1
25
19
14
8
6
4
3
3
1
1
1
1
1
43
33
24
13
10
7
6
5
4
3
2
1
1
58
45
33
18
14
10
8
7
5
4
3
3
2
96
74
55
30
22
16
14
11
8
7
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(2)
MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL NONMETALLIC TUBING (ENT)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3
2
1
1
1
1
1
0
0
0
0
6
5
4
1
1
1
1
1
1
0
0
10
9
7
3
3
2
1
1
1
1
1
19
16
13
6
5
4
3
3
1
1
1
26
22
17
9
7
6
5
4
3
2
1
43
36
29
15
12
9
8
7
5
4
3
RHW, RHW-23/0
4/0
0
0
0
0
1
1
1
1
1
1
3
2
TW14
12
10
8
7
5
4
1
13
10
7
4
22
17
13
7
40
31
23
13
55
42
32
17
92
71
52
29
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
4
3
3
1
8
7
5
3
15
12
9
5
27
21
17
10
37
29
23
14
61
49
38
23
RHWa, RHW-2a, TW, THW,
THHW, THW-2
6
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
0
0
0
0
0
2
1
1
1
1
1
1
0
0
4
3
2
2
1
1
1
1
1
7
5
5
4
3
2
1
1
1
10
8
7
6
4
3
3
2
1
17
13
11
9
6
5
5
4
3
THHN, THWN, THWN-214
12
10
8
6
4
3
2
10
7
4
2
1
1
1
1
18
13
8
5
3
1
1
1
32
23
15
8
6
4
3
2
58
42
26
15
11
7
5
5
80
58
36
21
15
9
8
6
132
96
60
35
25
15
13
11
THHN, THWN, THWN-21
1/0
2/0
3/0
4/0
1
0
0
0
0
1
1
1
1
0
1
1
1
1
1
3
3
2
1
1
5
4
3
3
2
8
7
5
4
4
XHHW, XHHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
7
5
4
1
1
1
1
1
1
0
0
0
0
13
10
7
4
3
1
1
1
1
1
1
1
0
22
17
13
7
5
4
3
2
1
1
1
1
1
40
31
23
13
9
7
6
5
3
3
2
1
1
55
42
32
17
13
9
8
6
5
4
3
3
2
92
71
52
29
21
15
13
11
8
7
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(3)
MAXIMUM NUMBER OF CONDUCTORS IN FLEXIBLE METALLIC CONDUIT (FMC)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
4
3
3
1
1
1
1
7
6
5
2
1
1
1
11
9
7
4
3
2
1
17
14
11
6
5
4
3
25
21
17
9
7
5
5
44
37
30
15
12
10
7
RHW, RHW-22
1
1/0
2/0
3/0
1
0
0
0
0
1
1
1
1
0
1
1
1
1
1
3
1
1
1
1
4
2
2
1
1
7
5
4
3
3
TW14
12
10
8
9
7
5
3
15
11
8
5
23
18
13
7
36
28
21
11
53
41
30
17
94
72
54
30
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
6
5
4
1
10
8
6
4
15
12
10
6
24
19
15
9
35
28
22
13
62
50
39
23
RHWa, RHW-2a, TW, THW,
THHW, THW-2
6
4
3
2
1
1/0
2/0
3/0
4/0
4/0
1
1
1
1
1
0
0
0
0
0
3
1
1
1
1
1
1
1
0
0
4
3
3
2
1
1
1
1
1
1
7
5
4
4
2
1
1
1
1
1
10
7
6
5
4
3
3
2
1
1
18
13
11
10
7
6
5
4
3
2
THHN, THWN, THWN-214
12
10
8
13
9
6
3
22
16
10
6
33
24
15
9
52
38
24
14
76
56
35
20
134
98
62
35
THHN, THWN, THWN-26
4
3
2
1
1/0
2/0
3/0
4/0
2
1
1
1
1
1
0
0
0
4
2
1
1
1
1
1
1
1
6
4
3
3
1
1
1
1
1
10
6
5
4
3
2
1
1
1
14
9
7
6
4
4
3
2
1
25
16
13
11
8
7
6
5
4
XHHW, XHHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
9
7
5
3
1
1
1
1
1
1
0
0
0
15
11
8
5
3
2
1
1
1
1
1
1
1
23
18
13
7
5
4
3
3
1
1
1
1
1
36
28
21
11
8
6
5
4
3
2
2
1
1
53
41
30
17
12
9
7
6
5
4
3
3
2
94
72
54
30
22
16
13
11
8
7
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(4)
MAXIMUM NUMBER OF CONDUCTORS IN INTERMEDIATE METALLIC CONDUIT (IMC)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
4
4
3
1
1
1
1
1
0
0
0
0
0
8
6
5
3
1
1
1
1
1
1
1
0
0
13
11
8
4
3
3
2
1
1
1
1
1
1
22
18
15
8
6
5
4
3
2
1
1
1
1
30
25
20
10
8
6
6
5
3
3
2
1
1
49
41
33
17
14
11
9
8
5
4
4
3
3
TW14
12
10
8
10
7
5
3
17
13
9
5
27
21
15
8
47
36
27
15
64
49
36
20
104
80
59
33
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
6
5
4
2
11
9
7
4
18
14
11
7
31
25
19
12
42
34
26
16
69
56
43
26
RHWa, RHW-2a, TW, THW,
THHW, THW-2
6
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
1
1
0
0
0
3
2
1
1
1
1
1
1
1
5
4
3
3
1
1
1
1
1
9
6
6
5
3
3
2
1
1
12
9
8
6
4
4
3
3
2
20
15
13
11
7
6
5
4
4
THHN, THWN, THWN-214
12
10
8
6
4
3
2
1
1/0
2/0
14
10
6
3
2
1
1
1
1
1
1
24
17
11
6
4
3
2
1
1
1
1
39
29
18
10
7
4
4
3
2
1
1
68
49
31
18
13
8
6
5
4
3
3
91
67
42
24
17
10
9
7
5
4
4
149
109
68
39
28
17
15
12
9
8
6
THHN, THWN, THWN-23/0
2/0
0
0
1
1
1
1
2
1
3
2
5
4
XHHW, XHHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
10
7
5
3
1
1
1
1
1
1
1
0
0
17
13
9
5
4
3
2
1
1
1
1
1
1
27
21
15
8
6
4
4
3
2
1
1
1
1
47
36
27
15
11
8
7
5
4
3
3
2
1
64
49
36
20
15
11
9
7
5
5
4
3
2
104
80
59
33
24
18
15
12
9
8
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(5)
MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-B)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
3/81/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
2
1
1
1
1
0
4
3
3
1
1
1
7
6
5
2
1
1
12
10
8
4
3
2
21
17
14
7
6
4
27
22
18
9
7
6
44
36
29
1
12
9
RHW, RHW-23
2
1
1/0
2/0
3/0
4/0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
1
1
1
1
1
0
0
1
1
1
1
1
1
1
4
3
1
1
1
1
1
5
4
3
2
1
1
1
8
7
5
4
3
3
2
TW14
12
10
8
5
4
3
1
9
7
5
3
15
12
9
5
25
19
14
8
44
33
25
14
57
43
32
18
93
71
53
29
RHWa, RGW-2a, THHW,
THW, THW-2
14
12
10
8
3
3
1
1
6
5
3
1
10
8
6
4
16
13
10
6
29
23
18
11
38
30
23
14
62
50
39
23
RHWa, RHW-2a, TW,
THW, THHW, THW-2
6
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
3
1
1
1
1
1
1
1
0
5
3
3
2
1
1
1
1
1
8
6
5
4
3
2
2
1
1
11
8
7
6
4
3
3
2
1
18
13
11
9
7
6
5
4
3
THHN, THWN, THWN-214
12
10
8
8
5
3
1
13
9
6
3
22
16
10
6
36
26
16
9
63
46
29
16
81
59
37
21
133
97
61
35
THHN, THWN, THWN-26
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
0
0
0
0
0
2
1
1
1
1
1
0
0
0
4
2
1
1
1
1
1
1
1
7
4
3
3
1
1
1
1
1
12
7
6
5
4
3
2
1
1
15
9
8
7
5
4
3
3
2
25
15
13
11
8
7
6
5
4
XHHW, XHHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
5
4
3
1
1
1
1
1
0
0
0
0
0
9
7
5
3
1
1
1
1
1
1
0
0
0
15
12
9
5
3
2
1
1
1
1
1
1
1
25
19
14
8
6
4
3
3
1
1
1
1
1
44
33
25
14
10
7
6
5
4
3
2
1
1
57
43
32
18
13
9
8
7
5
4
3
3
2
93
71
53
29
22
16
13
11
8
7
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(6)
MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-A)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
3/81/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
2
1
1
1
1
0
0
0
0
0
0
0
0
4
3
3
1
1
1
1
1
0
0
0
0
0
7
6
5
2
1
1
1
1
1
1
1
0
0
11
9
8
4
3
2
1
1
1
1
1
1
1
20
17
13
7
5
4
4
3
1
1
1
1
1
27
23
18
9
7
6
5
4
3
2
1
1
1
45
38
30
16
13
10
8
7
5
4
4
3
3
TW14
12
10
8
5
4
3
1
9
7
5
3
15
12
9
5
24
19
14
8
43
33
24
13
58
44
33
18
96
74
55
30
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
3
3
1
1
6
4
3
1
10
8
6
4
16
13
10
6
28
23
18
10
38
31
24
14
64
51
40
24
RHWa, RHW-2a, TW,
THW, THHW, THW-2
6
4
3
2
1
1
1
1
0
0
1
1
1
1
1
3
1
1
1
1
4
3
3
2
1
8
6
5
4
3
11
8
7
6
4
18
13
11
10
7
RHWa, RHW-2a, TW,
THW, THHW, THW-2
1/0
2/0
3/0
4/0
0
0
0
0
0
0
0
0
1
1
1
0
1
1
1
1
2
1
1
1
3
3
2
1
6
5
4
3
THHN, THWN, THWN-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
8
5
3
1
1
1
1
1
0
0
0
0
0
13
9
6
3
2
1
1
1
1
1
0
0
0
22
16
10
6
4
2
1
1
1
1
1
1
1
35
25
16
9
6
4
3
3
1
1
1
1
1
62
45
28
16
12
7
6
5
4
3
2
1
1
83
60
38
22
16
9
8
7
5
4
3
3
2
137
100
63
36
26
16
13
11
8
7
6
5
4
XHHW, XHHW-214
12
10
8
6
4
3
2
1
5
4
3
1
1
1
1
1
0
9
7
5
3
1
1
1
1
1
15
12
9
5
3
2
1
1
1
24
19
14
8
5
4
3
3
1
43
33
24
13
10
7
6
5
4
58
44
33
18
13
10
8
7
5
96
74
55
30
22
16
14
11
8
XHHW, XHHW-21/0
2/0
3/0
4/0
0
0
0
0
1
0
0
0
1
1
1
1
1
1
1
1
3
2
1
1
4
3
3
2
7
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(7)
MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE METAL CONDUIT (LFMC)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
4
3
3
1
1
1
1
1
0
0
0
0
0
7
6
5
2
1
1
1
1
1
1
1
0
0
12
10
8
4
3
2
1
1
1
1
1
1
1
21
17
14
7
6
4
4
3
1
1
1
1
1
27
22
18
9
7
6
5
4
3
2
1
1
1
44
36
29
15
12
9
8
7
5
4
3
3
2
TW14
12
10
8
9
7
5
3
15
12
9
5
25
19
14
8
44
33
25
14
57
43
32
18
93
71
53
29
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
6
5
3
1
10
8
6
4
16
13
10
6
29
23
18
11
38
30
23
14
62
50
39
23
RHWa, RHW-2a, TW,
THW, THHW, THW-2
6
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
1
0
0
0
0
3
1
1
1
1
1
1
1
0
5
3
3
2
1
1
1
1
1
8
6
5
4
3
2
2
1
1
11
8
7
6
4
3
3
2
1
18
13
11
9
7
6
5
4
3
THHN, THWN, THWN-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
13
9
6
3
2
1
1
1
1
1
0
0
0
22
16
10
6
4
2
1
1
1
1
1
1
1
36
26
16
9
7
4
3
3
1
1
1
1
1
63
46
29
16
12
7
6
5
4
3
2
1
1
81
59
37
21
15
9
8
7
5
4
3
3
2
133
97
61
35
25
15
13
11
8
7
6
5
4
XHHW, XHHW-214
12
10
8
9
7
5
3
15
12
9
5
25
19
14
8
44
33
25
14
57
43
32
18
93
71
53
29
XHHW, XHHW-26
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
1
1
0
0
0
3
2
1
1
1
1
1
1
1
6
4
3
3
1
1
1
1
1
10
7
6
5
4
3
2
1
1
13
9
8
7
5
4
3
3
2
22
16
13
11
8
7
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(8)
MAXIMUM NUMBER OF CONDUCTORS IN RIGID METAL CONDUIT (RMC)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
4
3
3
1
1
1
1
1
0
0
0
0
0
7
6
5
2
1
1
1
1
1
1
1
0
0
12
10
8
4
3
2
2
1
1
1
1
1
1
21
17
14
7
6
4
4
3
1
1
1
1
1
28
23
19
10
8
6
5
4
3
2
2
1
1
46
38
31
16
13
10
9
7
5
4
4
3
3
TW14
12
10
8
9
7
5
3
15
12
9
5
25
19
14
8
44
33
25
14
59
45
34
19
98
75
56
31
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
6
5
3
1
10
8
6
4
17
13
10
6
29
23
18
11
39
32
25
15
65
52
41
24
RHWa, RHW-2a, TW,
THW, THHW, THW-2
6
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
1
0
0
0
0
3
1
1
1
1
1
1
1
0
5
3
3
2
1
1
1
1
1
8
6
5
4
3
2
2
1
1
11
8
7
6
4
3
3
2
1
18
14
12
10
7
6
5
4
3
THHN, THWN, THWN-214
12
10
8
6
4
3
2
1
13
9
6
3
2
1
1
1
1
22
16
10
6
4
2
1
1
1
36
26
17
9
7
4
3
3
1
63
46
29
16
12
7
6
5
4
85
62
39
22
16
10
8
7
5
140
102
64
37
27
16
14
11
8
THHN, THWN, THWN-21/0
2/0
3/0
4/0
1
0
0
0
1
1
1
1
1
1
1
1
3
2
1
1
4
3
3
2
7
6
5
4
XHHW, XHHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
9
7
5
3
1
1
1
1
1
1
0
0
0
15
12
9
5
3
2
1
1
1
1
1
1
1
25
19
14
8
6
4
3
3
1
1
1
1
1
44
33
25
14
10
7
6
5
4
3
2
1
1
59
45
34
19
14
10
8
7
5
4
3
3
2
98
75
56
31
23
16
14
12
9
7
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(9)
MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT, SCHEDULE 80 (PVC-80)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
2
1
1
1
1
5
4
3
1
1
1
9
7
6
3
2
1
17
14
11
6
4
3
23
19
15
8
6
5
39
32
26
13
11
8
RHW, RHW-23
2
1
1/0
2/0
3/0
4/0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
1
1
1
1
1
1
0
3
3
1
1
1
1
1
4
4
2
1
1
1
1
7
6
4
3
3
3
2
TW14
12
10
8
6
5
3
1
11
9
6
3
20
15
11
6
35
27
20
11
49
38
28
15
82
63
47
26
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
4
3
2
1
8
6
5
3
13
10
8
5
23
19
15
9
32
26
20
12
55
44
34
20
RHWa, RHW-2a, TW,
THW, THHW, THW-2
6
4
3
2
1
1/0
1
1
1
1
0
0
1
1
1
1
1
1
3
3
2
1
1
1
7
5
4
3
2
1
9
7
6
5
3
3
16
12
10
8
6
5
RHWa, RHW-2a, TW,
THW, THHW, THW-2
2/0
3/0
4/0
0
0
0
1
0
0
1
1
1
1
1
1
2
1
1
4
3
3
THHN, THWN, THWN-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
9
6
4
2
1
1
1
1
0
0
0
0
0
17
12
7
4
3
1
1
1
1
1
1
1
0
28
20
13
7
5
3
3
2
1
1
1
1
1
51
37
23
13
9
6
5
4
3
2
1
1
1
70
51
32
18
13
8
7
6
4
3
3
2
1
118
86
54
31
22
14
12
10
7
6
5
4
3
XHHW, XHHW-214
12
10
8
6
6
5
3
1
1
11
9
6
3
2
20
15
11
6
4

35
27
20
118
49
38
28
15
11
82
63
47
26
19

(continued)

TABLE E3904.6(9)—continued
MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT, SCHEDULE 80 (PVC-80)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
XHHW, XHHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
6
5
3
1
1
1
1
1
0
0
0
0
0
11
9
6
3
2
1
1
1
1
1
1
1
0
20
15
11
6
4
3
3
2
1
1
1
1
1
35
27
20
11
8
6
5
4
3
2
1
1
1
49
38
28
15
11
8
7
6
4
3
3
2
1
82
63
47
26
19
14
12
10
7
6
5
4
3
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

TABLE E3904.6(10)
MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT SCHEDULE 40 (PVC-40)a

TYPE LETTERSCONDUCTOR SIZE
AWG/kcmil
TRADE SIZES
(inches)
1/23/4111/411/22
RHW, RHW-214
12
10
8
6
4
3
2
4
3
2
1
1
1
1
1
7
5
4
2
1
1
1
1
11
9
7
4
3
2
1
1
20
16
13
7
5
4
4
3
27
22
18
9
7
6
5
4
45
37
30
15
12
10
8
7
RHW, RHW-21
1/0
2/0
3/0
4/0
0
0
0
0
0
1
1
0
0
0
1
1
1
1
1
1
1
1
1
1
3
2
1
1
1
5
4
3
3
2
TW14
12
10
8
8
6
4
2
14
11
8
4
24
18
13
7
42
32
24
13
57
44
32
18
94
72
54
30
RHWa, RHW-2a, THHW,
THW, THW-2
14
12
10
8
5
4
3
1
9
8
6
3
16
12
10
6
28
22
17
10
38
30
24
14
63
50
39
23
RHWa, RHW-2a, TW,
THW, THHW, THW-2
6
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
0
0
0
0
0
2
1
1
1
1
1
1
1
0
4
3
3
2
1
1
1
1
1
8
6
5
4
3
2
1
1
1
11
8
7
6
4
3
3
2
1
18
13
11
10
7
6
5
4
3
THHN, THWN, THWN-214
12
10
8
11
8
5
3
21
15
9
5
34
25
15
9
60
43
27
16
82
59
37
21
135
99
62
36
THHN, THWN, THWN-26
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
1
1
0
0
0
4
2
1
1
1
1
1
1
1
6
4
3
3
1
1
1
1
1
11
7
6
5
3
3
2
1
1
15
9
8
7
5
4
3
3
2
26
16
13
11
8
7
6
5
4
XHHW, XHHW-214
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
8
6
4
2
1
1
1
1
1
1
0
0
0
14
11
8
4
3
2
1
1
1
1
1
1
1
24
18
13
7
5
4
3
3
1
1
1
1
1
42
32
24
13
10
7
6
5
3
3
2
1
1
57
44
32
18
13
9
8
7
5
4
3
3
2
94
72
54
30
22
16
13
11
8
7
6
5
4
For SI: 1 inch = 25.4 mm.
a. Types RHW, and RHW-2 without outer covering.

Related Code Sections


E3904.6 Power and Lighting Distribution, Conduit and Tubing Fill
The maximum number of conductors installed in conduit or tubing shall be in accordance with Tables E3904.6(1) through E3904.6(10). (300.17, Chapter 9 ...
2017 FBC - Residential, 6th edition > 39 Power and Lighting Distribution > E3904 General Installation Requirements > E3904.6 Conduit and Tubing Fill
E3904.6 Power and Lighting Distribution, Conduit and Tubing Fill
The maximum number of conductors installed in conduit or tubing shall be in accordance with Tables E3904.6(1) through E3904.6(10). TABLE E3904.6(1 ...
2014 FBC - Residential, 5th edition > 39 Power and Lighting Distribution > E3904 General Installation Requirements > E3904.6 Conduit and Tubing Fill
E3907.8 Power and Lighting Distribution, Cables
CONDUIT AND TUBING AREA FILLED BY CONDUCTORS 1 53 2 31 Over 2 40 ...
2014 FBC - Residential, 5th edition > 39 Power and Lighting Distribution > E3907 Cabinets and Panelboards > E3907.8 Cables
E3907.8 Power and Lighting Distribution, Cables
NUMBER OF CONDUCTORS MAXIMUM PERCENT OF CONDUIT AND TUBING AREA FILLED BY CONDUCTORS 1 53 2 31 Over 2 40 ...
2017 FBC - Residential, 6th edition > 39 Power and Lighting Distribution > E3907 Cabinets and Panelboards > E3907.8 Cables
E3905.12.3 Power and Lighting Distribution, Conduit Bodies
the cross-sectional area of the largest conduit or tubing to which they can be attached. The maximum number of conductors permitted shall ...
2017 FBC - Residential, 6th edition > 39 Power and Lighting Distribution > E3905 Boxes, Conduit Bodies and Fittings > E3905.12 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies > E3905.12.3 Conduit Bodies
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE