• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E3705.4.5 Conductors of Type SE Cable

2017 FBC - Residential, 6th edition > 37 Branch Circuit and Feeder Requirements > E3705 Conductor Sizing and Overcurrent Protection > E3705.4 Temperature Limitations > E3705.4.5 Conductors of Type SE Cable
JUMP TO FULL CODE CHAPTER
Where used as a branch circuit or feeder wiring method within the interior of a building and installed in thermal insulation, the ampacity of the conductors in Type SE cable assemblies shall be in accordance with the 60°C (140°F) conductor temperature rating. The maximum conductor temperature rating shall be permitted to be used for ampacity adjustment and correction purposes, provided that the final derated ampacity does not exceed that for a 60°C (140°F) rated conductor. [338.10(B)(4)(a)]

Related Code Sections


E3705.4.5 Branch Circuit and Feeder Requirements, Conductors of Type SE Cable
of the conductors in Type SE cable assemblies shall be in accordance with the 60°C (140°F) conductor temperature rating. The maximum conductor temperature ...
2017 FBC - Residential, 6th edition > 37 Branch Circuit and Feeder Requirements > E3705 Conductor Sizing and Overcurrent Protection > E3705.4 Temperature Limitations > E3705.4.5 Conductors of Type SE Cable
E3802.4 Wiring Methods, In Unfinished Basements and Crawl Spaces
Where type NM or SE cable is run at angles with joists in unfinished basements and crawl spaces, cable assemblies containing two or more conductors ...
2017 FBC - Residential, 6th edition > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.4 In Unfinished Basements and Crawl Spaces
E3802.4 Wiring Methods, In Unfinished Basements and Crawl Spaces
Where type NM or SE cable is run at angles with joists in unfinished basements and crawl spaces, cable assemblies containing two or more conductors ...
2014 FBC - Residential, 5th edition > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.4 In Unfinished Basements and Crawl Spaces
Section E3801 Wiring Methods, General Requirements
polyvinyl chloride conduit (Type PVC) RNC Rigid metallic conduit RMC Service entrance cable SE Surface raceways SR Underground feeder ...
2014 FBC - Residential, 5th edition > 38 Wiring Methods > E3801 General Requirements
Section E3801 Wiring Methods, General Requirements
sheathed cable NM Rigid polyvinyl chloride conduit (Type PVC) RNC Rigid metallic conduit RMC Service entrance cable SE Surface ...
2017 FBC - Residential, 6th edition > 38 Wiring Methods > E3801 General Requirements
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE