• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.963(f)(2) Conditions to Be Checked

OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.963 Testing and Test Facilities > 1926.963(f) Safety Check > 1926.963(f)(2) Conditions to Be Checked
JUMP TO FULL CODE CHAPTER
The test operator in charge shall conduct these routine safety checks before each series of tests and shall verify at least the following conditions:

1926.963(f)(2)(i)

Barriers and safeguards are in workable condition and placed properly to isolate hazardous areas;

1926.963(f)(2)(iii)

Clearly marked test-power disconnects are readily available in an emergency;

1926.963(f)(2)(iv)

Ground connections are clearly identifiable;

1926.963(f)(2)(v)

Personal protective equipment is provided and used as required by Subpart E of this part and by this subpart; and

1926.963(f)(2)(vi)

Proper separation between signal, ground, and power cables.

[79 FR 20710-20711, July 10, 2014]

1926.963(f)(2)(ii)

System test status signals, if used, are in operable condition;

Related Code Sections


1926.963(f)(2) Electric Power Transmission and Distribution, Conditions to Be Checked
The test operator in charge shall conduct these routine safety checks before each series of tests and shall verify at least the following conditions ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.963 Testing and Test Facilities > 1926.963(f) Safety Check > 1926.963(f)(2) Conditions to Be Checked
1926.963(f)(2)(vi) Electric Power Transmission and Distribution,
Proper separation between signal, ground, and power cables. [79 FR 20710-20711, July 10, 2014 ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.963 Testing and Test Facilities > 1926.963(f) Safety Check > 1926.963(f)(2) Conditions to Be Checked > 1926.963(f)(2)(vi)
1926.963(f) Electric Power Transmission and Distribution, Safety Check
in charge shall conduct these routine safety checks before each series of tests and shall verify at least the following conditions ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.963 Testing and Test Facilities > 1926.963(f) Safety Check
1926.964(c)(10) Electric Power Transmission and Distribution, Check Controls
The employer shall ensure that, before employees elevate an aerial lift into the work position, the employees check all controls (ground level ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.964 Overhead Lines and Live-Line Barehand Work > 1926.964(c) Live-Line Barehand Work > 1926.964(c)(10) Check Controls
1926.800(c) Underground Construction, Caissons, Cofferdams, and Compressed Air, Check-in/Check-Out
The employer shall maintain a check-in/check-out procedure that will ensure that above-ground personnel can determine an accurate count of the number ...
OSHA 1926 Construction > S Underground Construction, Caissons, Cofferdams, and Compressed Air > 1926.800 Underground Construction > 1926.800(c) Check-in/Check-Out
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING