• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R337.9.4.2 Conditions of Acceptance for ASTM E2726

Los Angeles Residential Code > 3 Building Planning > R337.9 Decking > R337.9.4 Requirements for Type of Ignition-Resistant Material in Section R337.9.3, Item 1 > R337.9.4.2 Conditions of Acceptance for ASTM E2726
JUMP TO FULL CODE CHAPTER
The ASTM E2726 test shall be conducted on a minimum of three test specimens and the conditions of acceptance in Items 1 and 2 below shall be met. If any one of the three test specimens does not meet the conditions of acceptance, three additional tests shall be run. All of the additional tests shall meet the conditions of acceptance.
  1. Absence of sustained flaming or glowing combustion of any kind at the conclusion of the 40-minute observation period.
  2. Absence of falling particles that are still burning when reaching the burner or floor.

Related Code Sections


709A.4.2 [SFM] Materials and Construction Methods for Exterior Wildfire Exposure, Conditions of Acceptance for ASTM E2726
The ASTM E2726 test shall be conducted on a minimum of three test specimens and the conditions of acceptance in Items 1 and 2 below shall be met. If ...
Los Angeles Building Code > 7A [SFM] Materials and Construction Methods for Exterior Wildfire Exposure > 709A Decking > 709A.4 Requirements for Type of Ignition-Resistant Material in Section 709A.3, Item 1 > 709A.4.2 Conditions of Acceptance for ASTM E2726
R337.9.4.2 Building Planning, Conditions of Acceptance for ASTM E2726
The ASTM E2726 test shall be conducted on a minimum of three test specimens and the conditions of acceptance in Items 1 and 2 below shall be met. If ...
Los Angeles Residential Code > 3 Building Planning > R337.9 Decking > R337.9.4 Requirements for Type of Ignition-Resistant Material in Section R337.9.3, Item 1 > R337.9.4.2 Conditions of Acceptance for ASTM E2726
R337.9.4.1 Building Planning, Conditions of Acceptance for ASTM E2632
The ASTM E2632 test shall be conducted on a minimum of three test specimens and the conditions of acceptance in Items 1 through 3 below shall be met ...
Los Angeles Residential Code > 3 Building Planning > R337.9 Decking > R337.9.4 Requirements for Type of Ignition-Resistant Material in Section R337.9.3, Item 1 > R337.9.4.1 Conditions of Acceptance for ASTM E2632
12-7A-5 [SFM] Materials and Construction Methods for Exterior Wildfire Exposure,
Impingement Exposure ASTM E2726/E2726M Standard Test Method for Evaluating the Fire Test Response of Deck Structures to Burning Brands ASTM ...
Los Angeles Building Code > 7A [SFM] Materials and Construction Methods for Exterior Wildfire Exposure > 703A Standards of Quality > 703A.7 Standards of Quality > 12-7A-5
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE