• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

F307.1.2 Condensate Drains, Piping and Wiring Chases

2017 FBC - Residential, 6th edition > F Florida Standard for Passive Radon-Resistant New Residential Building Construction > F307 Space Conditioning Systems > F307.1 Equipment Enclosures > F307.1.2 Condensate Drains, Piping and Wiring Chases
JUMP TO FULL CODE CHAPTER
Condensate drain pipe joints shall be sealed (chemical weld, soldered, etc.) gas tight and shall terminate outside the building perimeter at a height of at least 6 inches (152 mm) above the finished grade ground level. Chases through which the condensate and refrigerant lines run shall not terminate in the return sections of the air distribution system. Where chase lines terminate within the house or garage, they shall be sealed.

Related Code Sections


B307.1.2 Chapter 9B-52 F.A.C. Florida Standard for Passive Radon-Resistant Construction, Condensate Drains, Piping and Wiring Chases
Condensate drain pipe joints shall be sealed (chemical weld, soldered, etc.) gas tight and shall terminate outside the building perimeter at a height ...
2020 FBC - Building, 7th edition > B Chapter 9B-52 F.A.C. Florida Standard for Passive Radon-Resistant Construction > B301 Construction Requirements for Passive Radon Control > B307 Space Conditioning Systems > B307.1 Equipment Enclosures > B307.1.2 Condensate Drains, Piping and Wiring Chases
F307.1.2 Florida Standard for Passive Radon-Resistant New Residential Building Construction, Condensate Drains, Piping and Wiring Chases
Condensate drain pipe joints shall be sealed (chemical weld, soldered, etc.) gas tight and shall terminate outside the building perimeter at a height ...
2017 FBC - Residential, 6th edition > F Florida Standard for Passive Radon-Resistant New Residential Building Construction > F307 Space Conditioning Systems > F307.1 Equipment Enclosures > F307.1.2 Condensate Drains, Piping and Wiring Chases
F307.1.2 Florida Standard for Passive Radon-Resistant New Residential Building Construction, Condensate Drains, Piping and Wiring Chases
Condensate drain pipe joints shall be sealed (chemical weld, soldered, etc.) gas tight and shall terminate outside the building perimeter at a height ...
2020 FBC - Residential, 7th edition > F Florida Standard for Passive Radon-Resistant New Residential Building Construction > F307 Space Conditioning Systems > F307.1 Equipment Enclosures > F307.1.2 Condensate Drains, Piping and Wiring Chases
C406.1.1 Florida Standard for Mitigation of Radon in Existing Buildings, Condensate Drains
Condensate drains shall connect to air outside the building perimeter at a height of at least 6 inches (172 mm) above the finished grade ground level ...
2017 FBC - Building, 6th edition > C Florida Standard for Mitigation of Radon in Existing Buildings > C406 Space Conditioning and Ventilation Systems > C406.1 Mechanical System Connections > C406.1.1 Condensate Drains
C406.1.1 Florida Standard for Mitigation of Radon in Existing Buildings, Condensate Drains
Condensate drains shall connect to air outside the building perimeter at a height of at least 6 inches (172 mm) above the finished grade ground level ...
2020 FBC - Building, 7th edition > C Florida Standard for Mitigation of Radon in Existing Buildings > C4 Structural Sealing and HVAC System Balancing > C406 Space Conditioning and Ventilation Systems > C406.1 Mechanical System Connections > C406.1.1 Condensate Drains
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE