3310.9.1 Concrete Safety Manager
JUMP TO FULL CODE CHAPTER
A concrete safety manager shall be designated by the concrete contractor at those sites where the concrete portion of the project involves the pouring of a minimum of 2,000 cubic yards of concrete or such lesser amount as the commissioner may determine by rule. Concrete safety managers shall have five years of experience in concrete operations and shall have satisfactorily completed, within the five calendar years prior to registration, a thirty hour course approved by the commissioner that is sufficient to qualify the individual as a competent person under OSHA standards to oversee concrete operations, including such topics as formwork design, construction and stripping operations, rebar handling, and rigging. Concrete safety managers shall register with the department in the same manner as construction superintendents, and shall provide evidence of meeting the eligibility requirements set forth herein. No person shall perform the duties of a concrete safety manager without being registered as such with the department. The commissioner shall promulgate rules establishing the duration that such registration shall be valid and the requirements for renewal of the registration. The concrete safety manager shall be present during all concrete operations. For purposes of this section, "concrete operations" shall mean the pouring of concrete and the construction and stripping of concrete forms and related activities as specified by the commissioner.
Related Code Sections
3310.9.1 Safeguards During Construction or Demolition, Concrete Safety Manager
Beginning January 1, 2009, a concrete safety manager shall be designated by the concrete contractor at those sites where the concrete portion ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3310 Requirements for the Construction or Demolition of Major Buildings > 3310.9 Additional Site Safety Personnel > 3310.9.1 Concrete Safety Manager
3310.9.1 Safeguards During Construction or Demolition, Concrete Safety Manager
A concrete safety manager shall be designated by the concrete contractor at those sites where the concrete portion of the project involves ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3310 Requirements for the Construction or Demolition of Major Buildings > 3310.9 Additional Site Safety Personnel > 3310.9.1 Concrete Safety Manager
3305.3.3.2.2 Safeguards During Construction or Demolition, Discrepancies From the Formwork Design
the discrepancy. In addition, the site safety manager, site safety coordinator, and concrete safety manager, as applicable, shall be notified of discrepancies ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3305 Material Placement and Installation > 3305.3 Concrete Formwork > 3305.3.3 Formwork Inspection and Observation > 3305.3.3.2 Formwork Observation > 3305.3.3.2.2 Discrepancies From the Formwork Design
**3321.1 Safeguards During Construction or Demolition, Site Safety Training Required
safety manager, site safety coordinator, concrete safety manager, construction superintendent or a competent person at such site, as required ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3321 Construction Site Safety Training > **3321.1 Site Safety Training Required
Section 3310 Safeguards During Construction or Demolition, Requirements for the Construction or Demolition of Major Buildings
Beginning January 1, 2009, a concrete safety manager shall be designated ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3310 Requirements for the Construction or Demolition of Major Buildings