• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R404.1.3.2.1 Concrete Foundation Stem Walls Supporting Above-Grade Concrete Walls

2015 Michigan Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.2 Reinforcement for Foundation Walls > R404.1.3.2.1 Concrete Foundation Stem Walls Supporting Above-Grade Concrete Walls
JUMP TO FULL CODE CHAPTER
Foundation stem walls that support above-grade concrete walls shall be designed and constructed in accordance with this section.
  1. Stem walls not laterally supported at top. Concrete stem walls that are not monolithic with slabs-on-ground or are not otherwise laterally supported by slabs-on-ground shall comply with this section. Where unbalanced backfill retained by the stem wall is less than or equal to 18 inches (457 mm), the stem wall and above-grade wall it supports shall be provided with vertical reinforcement in accordance with Section R608.6 and Table R608.6(1), R608.6(2) or R608.6(3) for above-grade walls. Where unbalanced backfill retained by the stem wall is greater than 18 inches (457 mm), the stem wall and above-grade wall it supports shall be provided with vertical reinforcement in accordance with Section R608.6 and Table R608.6(4).
  2. Stem walls laterally supported at top. Concrete stem walls that are monolithic with slabs-on-ground or are otherwise laterally supported by slabs-on-ground shall be vertically reinforced in accordance with Section R608.6 and Table R608.6(1), R608.6(2) or R608.6(3) for above-grade walls. Where the unbalanced backfill retained by the stem wall is greater than 18 inches (457 mm), the connection between the stem wall and the slab-on-ground, and the portion of the slab-on-ground providing lateral support for the wall shall be designed in accordance with PCA 100 or with accepted engineering practice. Where the unbalanced backfill retained by the stem wall is greater than 18 inches (457 mm), the minimum nominal thickness of the wall shall be 6 inches (152 mm).

Related Code Sections


R404.1.3.2.1 Foundations, Concrete Foundation Stem Walls Supporting Above-Grade Concrete Walls
Foundation stem walls that support above-grade concrete walls shall be designed and constructed in accordance with this section. Stem walls ...
2015 Michigan Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.2 Reinforcement for Foundation Walls > R404.1.3.2.1 Concrete Foundation Stem Walls Supporting Above-Grade Concrete Walls
R608.6.1 Wall Construction, General
), R608.6(3) or R608.6(4). Above-grade concrete walls that are continuous with stem walls and not laterally supported by the slab-on-ground shall ...
2015 Michigan Residential Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.6 Above-Grade Wall Requirements > R608.6.1 General
R404.1.4 Foundations, Seismic Design Category D0, D1 or D2
shall comply with this section, and concrete foundation walls that support above-grade concrete walls shall comply with ACI 318, ACI 332 or PCA 100 ...
2015 Michigan Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.4 Seismic Design Category D0, D1 or D2
R608.6 Wall Construction, Above-Grade Wall Requirements
) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY For SI: 1 inch= 25.4 mm. FIGURE R608.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON ...
2015 Michigan Residential Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.6 Above-Grade Wall Requirements
R404.1.3.3 Foundations, Concrete, Materials for Concrete, and Forms
plastic insulation shall be permitted below grade on foundation walls in accordance with Section R318.4. Flat ICF wall system forms shall conform ...
2015 Michigan Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE