Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1805.5.7.2 Concrete Design

NYC Building Code 2014 > 18 Soils and Foundations > 1805 Shallow Foundations > 1805.5 Shallow Foundations > 1805.5.7 Pier Foundations > 1805.5.7.2 Concrete Design
JUMP TO FULL CODE CHAPTER
Where adequate lateral support is furnished by the surrounding materials defined in Section 1808.7, piers may be constructed of plain or reinforced concrete and the requirements of ACI 318 shall apply.

Exception: Where adequate lateral support is not provided, and the ratio of unsupported height to least horizontal dimension does not exceed three, piers of plain concrete shall be designed and constructed as pedestals in accordance with ACI 318. Where the unsupported height to least horizontal dimension exceeds three, piers shall be constructed of reinforced concrete, and shall conform to the requirements for columns in ACI 318.

Related Code Sections


1805.5.7.2 Soils and Foundations, Concrete Design
height to least horizontal dimension does not exceed three, piers of plain concrete shall be designed and constructed as pedestals in accordance with ACI ...
NYC Building Code 2014 > 18 Soils and Foundations > 1805 Shallow Foundations > 1805.5 Shallow Foundations > 1805.5.7 Pier Foundations > 1805.5.7.2 Concrete Design
Section 1912 Concrete, Anchorage to Concrete — Strength Design
The provisions of this section shall govern the strength design of anchors installed in concrete for purposes of transmitting structural loads from ...
NYC Building Code 2014 > 19 Concrete > 1912 Anchorage to Concrete — Strength Design
Section 1913 Concrete, Anchorage to Concrete — Strength Design
The provisions of this section shall govern the strength design of anchors installed in concrete for purposes of transmitting structural loads from ...
NYC Building Code 2008 > 19 Concrete > 1913 Anchorage to Concrete — Strength Design
1910.3 Concrete, Seismic Design Category B
Structures assigned to Seismic Design Category B, as determined in accordance with Section 1616, shall conform to the requirements for Seismic Design ...
NYC Building Code 2008 > 19 Concrete > 1910 Seismic Design Provisions > 1910.3 Seismic Design Category B
1913.1 Concrete, Scope
The provisions of this section shall govern the strength design of anchors installed in concrete for purposes of transmitting structural loads from ...
NYC Building Code 2008 > 19 Concrete > 1913 Anchorage to Concrete — Strength Design > 1913.1 Scope
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE