• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

403.2.3.3 Concrete and Masonry Walls

2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings > 403.2 Construction > 403.2.3 Structural Integrity of Interior Exit Stairways and Elevator Hoistway Enclosures > 403.2.3.3 Concrete and Masonry Walls
JUMP TO FULL CODE CHAPTER

Concrete or masonry walls shall be deemed to satisfy the requirements of Sections 403.2.3.1 and 403.2.3.2.

Related Code Sections


403.2.3.3 Special Detailed Requirements Based on Use and Occupancy, Concrete and Masonry Walls
Concrete or masonry walls shall be deemed to satisfy the requirements of Sections 403.2.3.1 and 403.2.3.2 ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings > 403.2 Construction > 403.2.3 Structural Integrity of Interior Exit Stairways and Elevator Hoistway Enclosures > 403.2.3.3 Concrete and Masonry Walls
403.2.3.3 Special Detailed Requirements Based on Use and Occupancy, Concrete and Masonry Walls
Concrete or masonry walls shall be deemed to satisfy the requirements of Sections 403.2.3.1 and 403.2.3.2 ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings > 403.2 Construction > 403.2.3 Structural Integrity of Interior Exit Stairways and Elevator Hoistway Enclosures > 403.2.3.3 Concrete and Masonry Walls
403.2.3.3 Special Detailed Requirements Based on Occupancy and Use, Concrete and Masonry Walls
Concrete or masonry walls shall be deemed to satisfy the requirements of Sections 403.2.3.1 and 403.2.3.2 ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 403 High-Rise Buildings > 403.2 Construction > 403.2.3 Structural Integrity of Interior Exit Stairways and Elevator Hoistway Enclosures > 403.2.3.3 Concrete and Masonry Walls
1709.1.1.2 Retrofitting, Concrete or Masonry Wall Below
Where the wall below a gable end wall is a concrete or masonry wall, connections shall be by one of the following methods. 2.1 Where the wall ...
2014 FBC - Existing Building, 5th edition > 17 Retrofitting > 1709 Connections to Wall Below > 1709.1 Requirements > 1709.1.1 Truss Gable End Wall > 1709.1.1.2 Concrete or Masonry Wall Below
1709.1.1.2 Retrofitting, Concrete or Masonry Wall Below
Where the wall below a gable end wall is a concrete or masonry wall, connections shall be by one of the following methods ...
2017 FBC - Existing Building, 6th edition > 17 Retrofitting > 1709 Connections to Wall Below > 1709.1 Requirements > 1709.1.1 Truss Gable End Wall > 1709.1.1.2 Concrete or Masonry Wall Below
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE