R406.1 Concrete and Masonry Foundation Dampproofing
JUMP TO FULL CODE CHAPTER
Except where required by Section R406.2 to be waterproofed, foundation walls that retain earth and enclose interior spaces and floors below grade shall be dampproofed from the higher of (a) the top of the footing or (b) 6 inches (152 mm) below the top of the basement floor, to the finished grade. Masonry walls shall have not less than 3/8-inch (9.5 mm) Portland cement parging applied to the exterior of the wall. The parging shall be dampproofed in accordance with one of the following:
- Bituminous coating.
- Three pounds per square yard (1.63 kg/m2) of acrylic modified cement.
- One-eighth-inch (3.2 mm) coat of surface-bonding cement complying with ASTM C887.
- Any material permitted for waterproofing in Section R406.2.
- Other approved methods or materials.
Exception: Parging of unit masonry walls is not required where a material is approved for direct application to the masonry.
Concrete walls shall be dampproofed by applying any one of the listed dampproofing materials or any one of the waterproofing materials listed in Section R406.2 to the exterior of the wall.
Related Code Sections
R406.1 Foundations, Concrete and Masonry Foundation Dampproofing
to the masonry. Concrete walls shall be dampproofed by applying any one of the listed dampproofing materials or any one of the waterproofing materials listed ...
Residential Code 2018 of Kansas > 4 Foundations > R406 Foundation Waterproofing and Dampproofing > R406.1 Concrete and Masonry Foundation Dampproofing
1805.2 Soils and Foundations, Dampproofing
be dampproofed in accordance with this section. Wood foundation systems shall be constructed in accordance with AWC PWF ...
Building Code 2018 of Kansas > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.2 Dampproofing
1805.3 Soils and Foundations, Waterproofing
Walls required to be waterproofed shall be of concrete or masonry and shall be designed and constructed ...
Building Code 2018 of Kansas > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.3 Waterproofing
1805.3.2 Soils and Foundations, Walls
Walls required to be waterproofed shall be of concrete or masonry and shall be designed and constructed to withstand the hydrostatic pressures ...
Building Code 2018 of Kansas > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.3 Waterproofing > 1805.3.2 Walls