2113.11.3 Concrete and Masonry Chimneys for Highheat Appliances
JUMP TO FULL CODE CHAPTER
Concrete and masonry chimneys for high-heat appliances shall comply with Sections 2113.1 through 2113.5.
Concrete and masonry chimneys for high-heat appliances shall extend not less than 20 feet (6096 mm) higher than any portion of any building within 50 feet (15 240 mm).
Concrete and masonry chimneys for high-heat appliances shall have approved clearance from buildings and structures to prevent overheating combustible materials, permit inspection and maintenance operations on the chimney and prevent danger of burns to persons.