605.10.1.1 Compression Joints
Go To Full Code Chapter
Compression joints shall include compression insert fittings and shall be joined to PEX-AL-PEX pipe through the compression of a split ring or compression nut around the outer circumference of the pipe, forcing the pipe material into the annular space formed by the ribs on the fitting.
Related Code Sections
605.10.1.1 Water Supply and Distribution, Compression Joints
Compression joints shall include compression insert fittings and shall be joined to PEX-AL-PEX pipe through the compression of a split ring ...
705.2.2 Sanitary Drainage, Mechanical Joints and Compression Joints
Mechanical joints for cast-iron pipe and fittings shall be of the elastomeric compression type or mechanical joint couplings. Compression type joints ...
P3003.4.2 Sanitary Drainage, Compression Gasket Joints
Compression gaskets for hub and spigot pipe and fittings shall conform to ASTM C564. Gaskets shall be compressed when the pipe is fully inserted ...
1203.13.2 Hydronic Piping, Mechanical and Compression Sleeve Joints
Mechanical and compression sleeve joints shall be installed in accordance with the manufacturer's instructions ...
1210.6.7.2 Hydronic Piping, Mechanical and Compression Sleeve Joints
Mechanical and compression sleeve joints shall be installed in accordance with the manufacturer's instructions ...