2305.3.8.2.7 Compression Chords
JUMP TO FULL CODE CHAPTER
Each end of each perforated shear wall segment shall be designed for a compression chord force, C, equal to the tension chord uplift force, T, calculated in Section 2305.3.8.2.4.
Related Code Sections
2305.3.8.2.7 Wood, Compression Chords
Each end of each perforated shear wall segment shall be designed for a compression chord force, C , equal to the tension chord uplift force, T ...
2010 Building Code of NY > 23 Wood > 2305 General Design Requirements for Lateral-Force-Resisting Systems > 2305.3 Design of Wood Shear Walls > 2305.3.8 Shear Walls With Openings > 2305.3.8.2 Perforated Shear Walls > 2305.3.8.2.7 Compression Chords
A111.4.3 Guidelines for the Seismic Retrofit of Existing Buildings, Chords
An analysis for diaphragm flexure need not be made, and chords need not be provided ...
2020 Existing Building Code of NYS > A Guidelines for the Seismic Retrofit of Existing Buildings > A111 Special Procedure > A111.4 Wood Diaphragms > A111.4.3 Chords
A111.4.3 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings, Chords
An analysis for diaphragm flexure need not be made, and chords need not be provided ...
Existing Building Code 2015 of New York State > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A111 Special Procedure > A111.4 Wood Diaphragms > A111.4.3 Chords
A111.4.3 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings, Chords
An analysis for diaphragm flexure need not be made, and chords need not be provided ...
2010 Existing Building Code of NY > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A111 Special Procedure > A111.4 Wood Diaphragms > A111.4.3 Chords