1926.1404(m) Components and Configuration
JUMP TO FULL CODE CHAPTER
The selection of components, and configuration of the equipment, that affect the capacity or safe operation of the equipment must be in accordance with:
Manufacturer instructions, prohibitions, limitations, and specifications. Where these are unavailable, a registered professional engineer familiar with the type of equipment involved must approve, in writing, the selection and configuration of components; or
Approved modifications that meet the requirements of § 1926.1434 (Equipment modifications).
Related Code Sections
1926.1404(m) Cranes & Derricks in Construction, Components and Configuration
The selection of components, and configuration of the equipment, that affect the capacity or safe operation of the equipment must be in accordance ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1404 Assembly/Disassembly--General Requirements (Applies to All Assembly and Disassembly Operations) > 1926.1404(m) Components and Configuration
1926.1441(b)(2) Cranes & Derricks in Construction, Components and Configuration
of components, and the configuration of the equipment, that affect the capacity or safe operation of the equipment complies with either ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1441 Equipment With a Rated Hoisting/Lifting Capacity of 2,000 Pounds or Less > 1926.1441(b) Assembly/Disassembly > 1926.1441(b)(2) Components and Configuration
1926.1441(b)(2)(i)(A) Cranes & Derricks in Construction,
professional engineer familiar with the type of equipment involved must approve, in writing, the selection and configuration of components; or ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1441 Equipment With a Rated Hoisting/Lifting Capacity of 2,000 Pounds or Less > 1926.1441(b) Assembly/Disassembly > 1926.1441(b)(2) Components and Configuration > 1926.1441(b)(2)(i) > 1926.1441(b)(2)(i)(A)
1926.1441(b)(2)(i)(B) Cranes & Derricks in Construction,
Approved modifications that meet the requirements of § 1926.1434 (Equipment modifications ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1441 Equipment With a Rated Hoisting/Lifting Capacity of 2,000 Pounds or Less > 1926.1441(b) Assembly/Disassembly > 1926.1441(b)(2) Components and Configuration > 1926.1441(b)(2)(i) > 1926.1441(b)(2)(i)(B)
1926.1441(b)(2)(ii) Cranes & Derricks in Construction, Post-Assembly Inspection
Upon completion of assembly, the equipment is inspected to ensure that it is in compliance with paragraph (b)(2)(i) of this section ( see § 1926.1412 ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1441 Equipment With a Rated Hoisting/Lifting Capacity of 2,000 Pounds or Less > 1926.1441(b) Assembly/Disassembly > 1926.1441(b)(2) Components and Configuration > 1926.1441(b)(2)(ii) Post-Assembly Inspection