• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3107F.2.5.6 Component Acceptance/Damage Criteria

Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3107F Structural Analysis and Design of Components > 3107F.2 Concrete Deck With Concrete or Steel Piles > 3107F.2.5 Concrete Piles > 3107F.2.5.6 Component Acceptance/Damage Criteria
JUMP TO FULL CODE CHAPTER

The maximum allowable concrete strains may not exceed the ultimate values defined in Section 3107F.2.5.5. The following limiting values (Table 31F-7-5) apply for each performance level for both existing and new structures. The "Level 1 or 2" refer to the seismic performance criteria (see Section 3104F.2.1).

For all non-seismic loading combinations, concrete components shall be designed in accordance with the ACI 318 [7.7] requirements.

Note that for existing facilities, the pile/deck hinge may be controlled by the capacity of the dowel reinforcement in accordance with Section 3107F.2.7.

Related Code Sections


3107F.2.5.6 [SLC] Marine Oil Terminals, Component Acceptance/Damage Criteria
-5) apply for each performance level for both existing and new structures. The "Level 1 or 2" refer to the seismic performance criteria (see Section ...
Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3107F Structural Analysis and Design of Components > 3107F.2 Concrete Deck With Concrete or Steel Piles > 3107F.2.5 Concrete Piles > 3107F.2.5.6 Component Acceptance/Damage Criteria
1908.10.3 Concrete, Acceptance Criteria
The average compressive strength of three cores from the in-place work or a single test panel shall equal or exceed 0.85 f' c with no single core ...
Los Angeles Building Code > 19 Concrete > 1908 Shotcrete > 1908.10 Strength Tests > 1908.10.3 Acceptance Criteria
1908.10.3 Concrete, Acceptance Criteria
The average compressive strength of three cores from the in-place work or a single test panel shall equal or exceed 0.85 f´ c with no single core ...
Los Angeles Building Code > 19 Concrete > 1908 Shotcrete > 1908.10 Strength Tests > 1908.10.3 Acceptance Criteria
1908A.10.3 Concrete, Acceptance Criteria
The average compressive strength of three cores from the in-place work or a single test panel shall equal or exceed 0.85 f ' c with no single core ...
Los Angeles Building Code > 19A Concrete > 1908A Shotcrete > 1908A.10 Strength Tests > 1908A.10.3 Acceptance Criteria
1708.2 Special Inspections and Tests, In-Situ Load Tests
Where a referenced material standard contains an applicable load test procedure and acceptance criteria, the test procedure and acceptance criteria ...
Los Angeles Building Code > 17 Special Inspections and Tests > 1708 In-Situ Load Tests > 1708.2 In-Situ Load Tests
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE