• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

912.1.1 Compliance With Chapter 8

Existing Building Code 2009 > 9 Change of Occupancy > 912 Change of Occupancy Classification > 912.1 General > 912.1.1 Compliance With Chapter 8
JUMP TO FULL CODE CHAPTER
The requirements of Chapter 8 shall be applicable throughout the building for the new occupancy classification based on the separation conditions set forth in Sections 912.1.1.1 and 912.1.1.2.

912.1.1.1 Change of Occupancy Classification Without Separation

Where a portion of an existing building is changed to a new occupancy classification and that portion is not separated from the remainder of the building with fire barriers having a fire-resistance rating as required in the International Building Code for the separate occupancy, the entire building shall comply with all of the requirements of Chapter 8 applied throughout the building for the most restrictive occupancy classification in the building and with the requirements of this chapter.

912.1.1.2 Change of Occupancy Classification With Separation

Where a portion of an existing building that is changed to a new occupancy classification and that portion is separated from the remainder of the building with fire barriers having a fire-resistance rating as required in the International Building Code for the separate occupancy, that portion shall comply with all the requirements of Chapter 8 for the new occupancy classification and with the requirements of this chapter.

Related Code Sections


912.1.1 Change of Occupancy, Compliance With Chapter 8
The requirements of Chapter 8 shall be applicable throughout the building for the new occupancy classification based on the separation conditions set ...
Existing Building Code 2009 > 9 Change of Occupancy > 912 Change of Occupancy Classification > 912.1 General > 912.1.1 Compliance With Chapter 8
1011.1.1 Change of Occupancy, Compliance With Chapter 9
The requirements of Chapter 9 shall be applicable throughout the building for the new occupancy classification based on the separation conditions set ...
Existing Building Code 2018 > 10 Change of Occupancy > 1011 Change of Occupancy Classification > 1011.1 General > 1011.1.1 Compliance With Chapter 9
1012.1.1 Change of Occupancy, Compliance With Chapter 9
The requirements of Chapter 9 shall be applicable throughout the building for the new occupancy classification based on the separation conditions set ...
Existing Building Code 2015 > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.1 General > 1012.1.1 Compliance With Chapter 9
1012.1.1 Change of Occupancy, Compliance With Chapter 9
The requirements of Chapter 9 shall be applicable throughout the building for the new occupancy classification based on the separation conditions set ...
Existing Building Code 2012 > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.1 General > 1012.1.1 Compliance With Chapter 9
1301.1.1 Performance Compliance Methods, Compliance With Other Methods
Alterations , additions and changes of occupancy to existing structures shall comply with the provisions of this chapter or with one ...
Existing Building Code 2018 > 13 Performance Compliance Methods > 1301 General > 1301.1 Scope > 1301.1.1 Compliance With Other Methods
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE