1011.1.1 Compliance With Building Code Chapter 9
Go To Full Code Chapter
The requirements of Chapter 9 of the Chicago Building Code shall be applicable throughout the existing building for the new occupancy classification based on the separation conditions set forth in Sections 1011.1.1.1 and 1011.1.1.2.
1011.1.1.1 Change of Occupancy Without Separation
Where a change of occupancy occurs in a portion of an existing building, and that portion is not separated from the remainder of the building with fire barriers having a fire-resistance rating as required in Section 508 the Chicago Building Code for separated occupancies, the entire building shall comply with all of the requirements of Chapter 9 of the Chicago Building Code applied throughout the building for the most restrictive occupancy classification in the building and with the requirements of this chapter.
1011.1.1.2 Change of Occupancy With Separation
Where a change of occupancy occurs in a portion of an existing building, and that portion is separated from the remainder of the building with fire barriers having a fire-resistance rating as required in Section 508 of the Chicago Building Code for separated occupancies or no separation is required by Section 508 of the Chicago Building Code, only that portion shall be required to comply with the requirements of Chapter 9 of the Chicago Building Code for the new occupancy classification and with the requirements of this chapter.
Related Code Sections
1011.1.1 Change of Occupancy, Compliance With Building Code Chapter 9
The requirements of Chapter 9 of the Chicago Building Code shall be applicable throughout the existing building for the new occupancy classification ...
301.5 Provisions for All Compliance Methods, Compliance With Accessibility
Accessibility requirements for existing buildings shall comply with ICC A117.1 as modified by Chapter 11 of the Chicago Building Code ...
1002.1 Change of Occupancy, Compliance With the Building Code
or occupancies described in Chapter 4 of the Chicago Building Code, the incidental use or special use or occupancy shall comply with all ...
501.1.1 Prescriptive Compliance Method, Compliance With Other Methods
Alterations, additions and changes of occupancy to existing buildings and structures shall comply with the provisions of this chapter or with one ...
601.1.1 Classification of Work, Compliance With Other Alternatives
Alterations, additions and changes of occupancy to existing buildings shall comply with the provisions of Chapters 7 through 12 or with one ...