• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1.4.4.4 Compliance Plan Schedule

California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 1 Definitions and Requirements > 1.4 Compliance Plans > 1.4.4 Compliance Plan Requirements > 1.4.4.4 Compliance Plan Schedule
JUMP TO FULL CODE CHAPTER

Provide a bar graph schedule which describes the schedule for compliance with the SPC and NPC seismic performance categories, indicating the schedule of the following major phases of the plan:

  1. Obtain a geotechnical report (if necessary);
  2. Architecture and engineering design/construction document preparation;
  3. Local approvals;
  4. Office review, approval and permitting;

    BUILDING
    NAME/
    DESIGNATION
    BUILDING
    TYPE (per
    Section 2.2.3)
    SPC
    existing
    SPC
    planned
    NPC
    existing
    NPC
    planned
  5. Approval of Department of Health Services Licensing and Certification, and any other required licensing;
  6. Permanent relocation of acute care services to other buildings or facilities (identify services affected);
  7. Temporary/interim relocation of acute care services to other buildings including the duration of the approved program flexibility plan pursuant to Health and Safety Code Section 1276.05;
  8. Construction period; and
  9. Beneficial occupancy.

Related Code Sections


1.4.4.4 Seismic Evaluation Procedures for Hospital Buildings, Compliance Plan Schedule
Provide a bar graph schedule which describes the schedule for compliance with the SPC and NPC seismic performance categories, indicating the schedule ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 1 Definitions and Requirements > 1.4 Compliance Plans > 1.4.4 Compliance Plan Requirements > 1.4.4.4 Compliance Plan Schedule
1.4.4.4 Seismic Evaluation Procedures for Hospital Buildings, Compliance Plan Schedule
Provide a bar graph schedule which describes the schedule for compliance with the SPC and NPC seismic performance categories, indicating the schedule ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 1 Definitions and Requirements > 1.4 Compliance Plans > 1.4.4 Compliance Plan Requirements > 1.4.4.4 Compliance Plan Schedule
1.4 Seismic Evaluation Procedures for Hospital Buildings, Compliance Plans
the following elements: An Existing Site/Campus Description; A Compliance Plan Description; A Compliance Site Plan; A Compliance Plan Schedule; and An ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 1 Definitions and Requirements > 1.4 Compliance Plans
1.4.5 Seismic Evaluation Procedures for Hospital Buildings, Compliance Plan Update/Change Notification
an amended Compliance Plan. Changes are defined as alterations to the planned level of seismic performance or compliance schedule. Submittal ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 1 Definitions and Requirements > 1.4 Compliance Plans > 1.4.5 Compliance Plan Update/Change Notification
1.4.5 Seismic Evaluation Procedures for Hospital Buildings, Compliance Plan Update/Change Notification
an amended Compliance Plan. Changes are defined as alterations to the planned level of seismic performance or compliance schedule. Submittal ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 1 Definitions and Requirements > 1.4 Compliance Plans > 1.4.5 Compliance Plan Update/Change Notification
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE