8.6.7.9.6 Compensating Means
Go To Full Code Chapter
Mine elevator compensating chains shall be replaced when any portion of the link diameter is less than 80% of the original link diameter.
Upcodes Diagrams
Related Code Sections
2.21.4 Electric Elevators, Compensation Means
Compensation means, such as compensating ropes or chains or other mechanical means and their attachments (except for safety hooks, where used) to tie ...
8.6.7.9.6 General Requirements, Compensating Means
Mine elevator compensating chains shall be replaced when any portion of the link diameter is less than 80% of the original link diameter ...
2.15.17 Electric Elevators, Fastening of Compensation Means
Fastenings to the car of the suspension ropes' compensation means shall conform to 2.21.4 ...
5.9.20.1 Special Application Elevators, Suspension and Compensating Means and Governor Ropes
When elevator suspension or compensating means or governor ropes are exposed to an environment that will cause corrosion, surface pitting, or loss ...
8.6.2.5 General Requirements, Repair of Suspension and Compensating Means and Governor Ropes
Suspension and compensating members and governor ropes shall not be lengthened or repaired by splicing (see 8.7.2.21) ...