Companion seats shall comply with 802.3.
802.3.1 Alignment
In row seating, companion seats shall be located to provide shoulder alignment with adjacent wheelchair spaces.  The shoulder alignment point of the wheelchair space shall be measured 36 inches (915 mm) from the front of the wheelchair space.  The floor surface of the companion seat shall be at the same elevation as the floor surface of the wheelchair space.
802.3.2 Type
Companion seats shall be equivalent in size, quality, comfort, and amenities to the seating in the immediate area.  Companion seats shall be permitted to be movable.

Related Code Sections

1002.4.7 Recreation Facilities, Companion Seats
is not required to be centered within the amusement ride, a companion seat shall be provided for each wheelchair space ...
221.3 Scoping Requirements, Companion Seats
At least one companion seat complying with 802.3 shall be provided for each wheelchair space required by 221.2.1 ...
(g) 28 CFR 35.151 New Construction and Alterations, Assembly Areas
wheelchair spaces and companion seats by section 221.2.3.1 of the 2010 Standards and have seating encircling, in whole or in part, a field of play ...
(f) 28 CFR Part 36, Subpart D — New Construction and Alterations, Assembly Areas
and companion seats are dispersed to all levels that include seating served by an accessible route; (2) In assembly areas that are required to horizontally ...