1926.1419(m) Communication With Multiple Cranes/Derricks
JUMP TO FULL CODE CHAPTER
Where a signal person(s) is in communication with more than one crane/derrick, a system must be used for identifying the crane/derrick each signal is for, as follows:
for each signal, prior to giving the function/direction, the signal person must identify the crane/derrick the signal is for, or
must use an equally effective method of identifying which crane/derrick the signal is for.
[75 FR 48153, August 9, 2010]
[75 FR 48153, August 9, 2010]
Related Code Sections
1926.1419(m) Cranes & Derricks in Construction, Communication With Multiple Cranes/Derricks
Where a signal person(s) is in communication with more than one crane/derrick, a system must be used for identifying the crane/derrick each signal ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1419 Signals--General Requirements > 1926.1419(m) Communication With Multiple Cranes/Derricks
1926.1437(j) Cranes & Derricks in Construction, Working With a Diver
: If a crane/derrick is used to get a diver into and out of the water, it must not be used for any ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1437 Floating Cranes/Derricks and Land Cranes/Derricks on Barges > 1926.1437(j) Working With a Diver
1926.1417(u) Cranes & Derricks in Construction, Traveling With a Load
Traveling with a load is prohibited if the practice is prohibited by the manufacturer ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1417 Operation > 1926.1417(u) Traveling With a Load
1926.1436 Cranes & Derricks in Construction, Derricks
base-mounted) and operating ropes. Derricks include: A-frame, basket, breast, Chicago boom, gin pole (except gin poles used for erection of communication ...
1926.1441(a) Cranes & Derricks in Construction,
of the load) (except for § 1926.1425(c)(3) (qualified rigger)); § 1926.1426 (Free fall and controlled load lowering); § 1926.1432 (Multiple crane/derrick lifts ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1441 Equipment With a Rated Hoisting/Lifting Capacity of 2,000 Pounds or Less > 1926.1441(a)