// CODE SNIPPET
704.3 Commercial Sinks
JUMP TO FULL CODE CHAPTER
Pot sinks, scullery sinks, dishwashing
sinks, silverware sinks, and other similar fixtures shall be connected directly to the drainage system. A floor
drain shall be provided adjacent to the fixture, and the
fixture shall be connected on the sewer side of the floor
drain trap, provided that no other drainage line is connected
between the floor drain waste connection and the fixture
drain. The fixture and floor drain shall be trapped and
vented in accordance with this code.
Related Code Sections
704.3 Sanitary Drainage, Commercial Sinks
Pot sinks, scullery sinks, dishwashing
sinks, silverware sinks, and other similar fixtures shall be connected directly to the drainage system. A ...
California Plumbing Code 2016 > 7 Sanitary Drainage > 704.0 Fixture Connections (Drainage) > 704.3 Commercial Sinks
704.3 Sanitary Drainage, Commercial Sinks
Pot sinks, scullery sinks, dishwashing
sinks, silverware sinks, and other similar fixtures
shall be connected directly to the drainage system. A ...
California Plumbing Code 2019 > 7 Sanitary Drainage > 704.0 Fixture Connections (Drainage) > 704.3 Commercial Sinks
11B-606.7 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Sink Depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B -306 ...
California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-606 Lavatories and Sinks > 11B-606.7 Sink Depth
1503.1.1 Alternate Water Sources for Nonpotable Applications, Allowed Uses
Allowed uses shall include
water closets, urinals, trap primers for floor drains and
floor sinks, industrial or commercial cooling or air ...
California Plumbing Code 2016 > 15 Alternate Water Sources for Nonpotable Applications > 1503.0 Recycled Water Supply Systems in Buildings > 1503.1 General > 1503.1.1 Allowed Uses
1505.1.1 Alternate Water Sources for Nonpotable Applications, Allowed Uses
Allowed uses shall include water closets, urinals, trap primers for floor drains and floor sinks, industrial or commercial cooling or air ...
California Plumbing Code 2019 > 15 Alternate Water Sources for Nonpotable Applications > 1505.0 Recycled Water Supply Systems in Buildings > 1505.1 General > 1505.1.1 Allowed Uses