• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

102.3.1 Commercial HVAC Systems

California Mechanical Code 2019 > 1 Administration > 102.0 Applicability > 102.3 Maintenance > 102.3.1 Commercial HVAC Systems
JUMP TO FULL CODE CHAPTER
Commercial HVAC systems both existing and new, and parts thereof shall be inspected and maintained in operating condition in accordance with ASHRAE/ACCA 180. The owner or the owner's designated agent shall be responsible for maintenance of mechanical systems and equipment. To determine compliance with this subsection, the Authority Having Jurisdiction shall be permitted to cause a HVAC system to be reinspected.

Related Code Sections


102.3.1 Administration, Commercial HVAC Systems
Commercial HVAC systems both existing and new, and parts thereof shall be inspected and maintained in operating condition in accordance with ASHRAE ...
California Mechanical Code 2016 > 1 Administration > 102.0 Applicability > 102.3 Maintenance > 102.3.1 Commercial HVAC Systems
102.3.1 Administration, Commercial HVAC Systems
Commercial HVAC systems both existing and new, and parts thereof shall be inspected and maintained in operating condition in accordance with ASHRAE ...
California Mechanical Code 2019 > 1 Administration > 102.0 Applicability > 102.3 Maintenance > 102.3.1 Commercial HVAC Systems
909.4.4 Fire Protection Systems, HVAC Systems
The design shall consider the effects of the heating, ventilating and air-conditioning (HVAC) systems on both smoke and fire transport. The analysis ...
California Building Code 2016 (Vol 1 & 2) > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.4 Analysis > 909.4.4 HVAC Systems
909.4.4 Fire Protection and Life Safety Systems, HVAC Systems
The design shall consider the effects of the heating, ventilating and air-conditioning (HVAC) systems on both smoke and fire transport. The analysis ...
California Building Code 2019 (Vol 1 & 2) > 9 Fire Protection and Life Safety Systems > 909 Smoke Control Systems > 909.4 Analysis > 909.4.4 HVAC Systems
5.410.4.3.1 Nonresidential Mandatory Measures, HVAC Balancing
In addition to testing and adjusting, before a new space-conditioning system serving a building or space is operated for normal use, balance ...
California Green Building Standards Code 2019 > 5 Nonresidential Mandatory Measures > 5.410 Building Maintenance and Operation > 5.410.4 Testing and Adjusting. New Buildings Less Than 10,000 Square Feet > 5.410.4.3 Procedures > 5.410.4.3.1 HVAC Balancing
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE