// CODE SNIPPET
104-13 Commercial and Manufacturing Use Modifications
JUMP TO FULL CODE CHAPTER
In Subdistricts A and C, the commercial and manufacturing use regulations of the underlying C6 Districts are modified as set forth in Section 104-132 (Use Groups 16, 17 and 18).
In Subdistrict B, the commercial use regulations of the underlying M1 District are modified as set forth in Section 104-131 (Use Group 6A).
In Subdistrict B, the provisions of Section 42-12 (Use Groups 3A, 6A, 6B, 6D, 6F, 7B, 7C, 7D, 7E, 8, 9B, 9C, 10A, 10B, 10C, 11, 12A, 12C, 12D, 12E, 13, 14 and 16), shall be modified to permit food stores, including supermarkets, grocery stores or delicatessen stores, without limitation as to floor area per establishment.
In Subdistricts A and C, the following uses in Use Groups 16, 17 and 18 are permitted, subject to the performance standards for an M1 District set forth in Section 42-20.
Such uses may locate in the same building, or in an abutting building containing a residential use or a community facility use with sleeping accommodations listed in Section 104-12 (Community Facility Use Modifications), only in accordance with the certification provisions of Section 104-14.
From Use Group 16A:
Animal hospitals or kennels
Automobile, motorcycle, trailer or boat sales, enclosed only
Carpentry, custom woodworking or custom furniture making shops
Motorcycle or motor scooter rental establishments, enclosed only
Trade schools for adults
From Use Group 16B:
Automobile, truck, motorcycle or trailer repairs
Automobile laundries, provided that the zoning lot contains reservoir space for not less than 10 automobiles per washing lane
Automotive service stations, open or enclosed, provided that facilities for lubrication, minor repairs or washing are permitted only if located within a completely enclosed building
From Use Group 16C:
Commercial or public utility vehicle storage, open or enclosed, including accessory motor fuel pumps
Public transit yards, open or enclosed, including accessory motor fuel pumps
From Use Group 16D:
Moving or storage offices, with no limitation as to storage or floor area per establishment
Warehouses
Wholesale establishments, with no limitation on accessory storage
From Use Group 17A:
Produce or meat markets
From Use Group 17B:
Advertising displays
Apparel or other textile products, from textiles or other materials, including hat bodies or similar products
Ceramic products, including pottery, small glazed tile or similar products
Food products, except slaughtering of meat or preparation of fish for packing
Leather products, including shoes, machine belting or similar products
Luggage
Musical instruments, including pianos or organs
Optical equipment, clocks or similar precision instruments
Perfumes or perfumed soaps, compounding only
Printing or publishing, with no limitation on floor area per establishment
Scenery construction
Textiles, spinning, weaving, manufacturing, dyeing, printing, knit goods, yarn, thread or cordage
Toys
Wood products, including furniture, boxes, crates, baskets, pencils, cooperage works or similar products
From Use Group 17C:
Public transit, railroad or electric utility substations, open or enclosed, with no limitation as to size
From Use Group 18A:
Manufacturing of beverages, alcoholic or breweries
Related Code Sections
Section G501 Flood-Resistant Construction, Modifications
of the department for any subsequent additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 ...
Section 504 General Building Heights and Areas; Separation of Occupancies, Height Modifications
hangars, aircraft paint hangars and buildings used for the manufacturing of aircraft shall not be limited if the building is provided with an automatic fire ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 504 Height Modifications
Section G501 Flood-Resistant Construction, Modifications
of the department for any subsequent additions, modifications or deletions that may have been made to this standard in accordance with Section 28-103.19 ...
1004.1.2 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.1, the commissioner may establish a lower ...
NYC Building Code 2014 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.2 Modifications
1004.1.3.1 Means of Egress, Modifications
Where the actual number of occupants of any space will be significantly lower than listed in Table 1004.1.3, the commissioner may establish a lower ...
NYC Building Code 2022 > 10 Means of Egress > 1004 Occupant Load > 1004.1 Design Occupant Load > 1004.1.3 Areas Without Fixed Seating > 1004.1.3.1 Modifications