• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2703.10.1.2 Combustible Tools

Minnesota Fire Code 2015 > 27 Semiconductor Fabrication Facilities > 2703 General Safety Provisions > 2703.10 Automatic Sprinkler System > 2703.10.1 Workstations and Tools > 2703.10.1.2 Combustible Tools
JUMP TO FULL CODE CHAPTER
Where the horizontal surface of a combustible tool is obstructed from ceiling sprinkler discharge, automatic sprinkler protection that covers the horizontal surface of the tool shall be provided.
Exceptions:
  1. An automatic gaseous fire-extinguishing local surface application system shall be allowed as an alternative to sprinklers. Gaseous-extinguishing systems shall be actuated by infrared (IR) or ultraviolet/infrared (UV/IR) optical detectors.
  2. Tools constructed of materials that are listed as Class 1 or Class 2 in accordance with UL 2360 or approved for use without internal fire-extinguishing system protection.

Related Code Sections


2703.10.1.2 Semiconductor Fabrication Facilities, Combustible Tools
Where the horizontal surface of a combustible tool is obstructed from ceiling sprinkler discharge, automatic sprinkler protection that covers ...
2020 Minnesota State Fire Code > 27 Semiconductor Fabrication Facilities > 2703 General Safety Provisions > 2703.10 Automatic Sprinkler System > 2703.10.1 Workstations and Tools > 2703.10.1.2 Combustible Tools
2703.10.1.2 Semiconductor Fabrication Facilities, Combustible Tools
Where the horizontal surface of a combustible tool is obstructed from ceiling sprinkler discharge, automatic sprinkler protection that covers ...
Minnesota Fire Code 2015 > 27 Semiconductor Fabrication Facilities > 2703 General Safety Provisions > 2703.10 Automatic Sprinkler System > 2703.10.1 Workstations and Tools > 2703.10.1.2 Combustible Tools
2403.4.1 Flammable Finishes, Tools
Scrapers, spuds and other tools used for cleaning purposes shall be constructed of nonsparking materials ...
2020 Minnesota State Fire Code > 24 Flammable Finishes > 2403 Protection of Operations > 2403.4 Operations and Maintenance > 2403.4.1 Tools
2403.4.1 Flammable Finishes, Tools
Scrapers, spuds and other tools used for cleaning purposes shall be constructed of nonsparking materials ...
Minnesota Fire Code 2015 > 24 Flammable Finishes > 2403 Protection of Operations > 2403.4 Operations and Maintenance > 2403.4.1 Tools
2703.10.1.1 Semiconductor Fabrication Facilities, Combustible Workstations
A sprinkler head shall be installed within each branch exhaust connection or individual plenums of workstations of combustible construction. The ...
Minnesota Fire Code 2015 > 27 Semiconductor Fabrication Facilities > 2703 General Safety Provisions > 2703.10 Automatic Sprinkler System > 2703.10.1 Workstations and Tools > 2703.10.1.1 Combustible Workstations
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE