Section 805 Combustible Materials in Type I and II Construction
JUMP TO FULL CODE CHAPTER
Floor sleepers, bucks and nailing blocks shall not be constructed of combustible materials, unless the space between the fire-resistance-rated floor construction and the flooring is either solidly filled with approved noncombustible materials or fireblocked in accordance with Section 717, and provided that such open spaces shall not extend under or through permanent partitions or walls.
Wood finish flooring is permitted to be attached directly to the embedded or fireblocked wood sleepers and shall be permitted where cemented directly to the top surface of approved fire-resistance-rated floor construction or directly to a wood subfloor attached to sleepers as provided for in Section 805.1.1.
Combustible insulating boards not more than 1 / 2 inch (12.7 mm) thick and covered with approved finish flooring are permitted where attached directly to a noncombustible floor assembly or to wood subflooring attached to sleepers as provided for in Section 805.1.1.
Related Code Sections
Section 603 Types of Construction, Combustible Material in Types I and II Construction
Combustible materials shall be permitted in buildings of Type I or II construction in the following applications and in accordance with Sections ...
Building Code 2015 of New York State > 6 Types of Construction > 603 Combustible Material in Types I and II Construction
Section 603 Types of Construction, Combustible Material in Types I and II Construction
Combustible materials shall be permitted in buildings of Type I or II construction in the following applications and in accordance with Sections ...
2020 Building Code of New York State > 6 Types of Construction > 603 Combustible Material in Types I and II Construction
Section 603 Types of Construction, Combustible Material in Type I and II Construction
Combustible materials shall be permitted in buildings of Type I or Type II construction in the following applications and in accordance with Sections ...
2010 Building Code of NY > 6 Types of Construction > 603 Combustible Material in Type I and II Construction
Section 805 Interior Finishes, Combustible Materials in Type I and II Construction
Combustible materials installed on or embedded in floors of buildings of Type I or II construction shall comply with Sections 805.1.1 through 805.1.3 ...
2010 Building Code of NY > 8 Interior Finishes > 805 Combustible Materials in Type I and II Construction
Section 805 Interior Finishes, Combustible Materials in Types I and II Construction
Combustible materials installed on or embedded in floors of buildings of Type I or II construction shall comply with Sections 805.1.1 through 805.1.3 ...
Building Code 2015 of New York State > 8 Interior Finishes > 805 Combustible Materials in Types I and II Construction