918.5 Combustible Material Adjacent to Cooking Top
JUMP TO FULL CODE CHAPTER
A portion of combustible material adjacent to a cooking top section
of a food service range, even though listed for close-to-wall
installation, that is not shielded from the wall by a high
shelf, warming closet, and so on, shall be protected as specified
in Section 918.2 for a distance of not less than 2 feet (610
mm) above the surface of the cooking top. [NFPA 54:10.12.5]
Related Code Sections
918.5 Installation of Specific Appliances, Combustible Material Adjacent to Cooking Top
) horizontally for a distance of up to 2 feet
(610 mm) above the surface of the cooking top where the
combustible material is not completely shielded by high ...
Los Angeles Mechanical Code > 9 Installation of Specific Appliances > 918.0 Food Service Appliance, Floor Mounted > 918.5 Combustible Material Adjacent to Cooking Top
918.5 Installation of Specific Appliances, Combustible Material Adjacent to Cooking Top
A portion of combustible material adjacent to a cooking top section
of a food service range, even though listed for close-to-wall
installation ...
Los Angeles Mechanical Code > 9 Installation of Specific Appliances > 918.0 Food Service Appliance, Floor Mounted > 918.5 Combustible Material Adjacent to Cooking Top
920.4 Installation of Specific Appliances, Built-In Units
Unlisted built-in
household cooking appliances shall not be installed in
or adjacent to combustible material ...
Los Angeles Mechanical Code > 9 Installation of Specific Appliances > 920.0 Household Cooking Appliances > 920.4 Built-In Units
921.4 Installation of Specific Appliances, Built-In Units
Unlisted built-in
household cooking appliances shall not be installed in or
adjacent to combustible material ...
Los Angeles Mechanical Code > 9 Installation of Specific Appliances > 921.0 Household Cooking Appliances > 921.4 Built-In Units
920.3 Installation of Specific Appliances, Floor-Mounted Units
adjacent combustible
material. A clearance of not less than 36
inches (914 mm) shall be provided between the top
of the heater section and the bottom ...
Los Angeles Mechanical Code > 9 Installation of Specific Appliances > 920.0 Household Cooking Appliances > 920.3 Floor-Mounted Units