// CODE SNIPPET
808.4 Combustible Lockers
JUMP TO FULL CODE CHAPTER
Where lockers constructed of combustible materials are used, the lockers shall be considered to be interior finish and shall comply with Section 803.
Exception: Lockers constructed entirely of wood and noncombustible materials shall be permitted to be used wherever interior finish materials are required to meet a Class C classification in accordance with Section 803.1.2.
Related Code Sections
808.4 Interior Finish, Decorative Materials and Furnishings, Combustible Lockers
Where lockers constructed of combustible materials are used, the lockers shall be considered to be interior finish and shall comply with Section 803 ...
2018 Philadelphia Fire Code > 8 Interior Finish, Decorative Materials and Furnishings > 808 Furnishings Other Than Upholstered Furniture and Mattresses or Decorative Materials in New and Existing Buildings > 808.4 Combustible Lockers
5704.4.3 Flammable and Combustible Liquids, Spill Control and Secondary Containment
on approved containment pallets in accordance with Section 5004.2.3 and containers stored in cabinets and lockers with integral spill containment ...
2018 Philadelphia Fire Code > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.4 Outdoor Storage of Containers and Portable Tanks > 5704.4.3 Spill Control and Secondary Containment
1109.12.1 Accessibility, Dressing, Fitting and Locker Rooms
Where dressing rooms, fitting rooms or locker rooms are provided, at least 5 percent, but not less than one, of each type of use in each cluster ...
2018 Philadelphia Building Code > 11 Accessibility > 1109 Other Features and Facilities > 1109.12 Service Facilities > 1109.12.1 Dressing, Fitting and Locker Rooms
305.8.12 Provisions for All Compliance Methods, Dressing, Fitting and Locker Rooms
Where it is technically infeasible to provide accessible dressing, fitting or locker rooms at the same location as similar types of rooms, one ...
2018 Philadelphia Existing Building Code > 3 Provisions for All Compliance Methods > 305 Accessibility for Existing Buildings > 305.8 Scoping for Alterations > 305.8.12 Dressing, Fitting and Locker Rooms
807.5 Interior Finish, Decorative Materials and Furnishings, Occupancy-Based Requirements
Storage in metal lockers, provided the minimum required egress width is maintained ...
2018 Philadelphia Fire Code > 8 Interior Finish, Decorative Materials and Furnishings > 807 Decorative Materials and Artificial Decorative Vegetation in New and Existing Buildings > 807.5 Occupancy-Based Requirements