R302.13 Combustible Insulation
JUMP TO FULL CODE CHAPTER
Combustible insulation shall be separated a minimum of 3 inches (76 mm) from
recessed lighting fixtures, fan motors, and other heat-producing devices.
Exception: When heat-producing devices are listed for lesser clearances, combustible insulation complying with the listing requirements shall be separated in accordance with the conditions stipulated in the listing.
Recessed lighting fixtures installed in the building thermal envelope shall be installed in accordance with the manufacturer's installation instructions.
R 408.30538
Recessed lighting fixtures installed in the building thermal envelope shall be installed in accordance with the manufacturer's installation instructions.
R 408.30538
Related Code Sections
R302.13 Building Planning, Combustible Insulation
Combustible insulation shall be separated a minimum of 3 inches (76 mm) from
recessed lighting fixtures, fan motors, and other heat-producing devices ...
2015 Michigan Residential Code > 3 Building Planning > R302 Fire-Resistant Construction > R302.13 Combustible Insulation
805.1.3 Interior Finishes, Insulating Boards
Combustible insulating boards
not more than 1 / 2 inch (12.7 mm) thick and covered with
finish flooring are permitted where attached directly ...
2015 Michigan Building Code > 8 Interior Finishes > 805 Combustible Materials in Types I and II Construction > 805.1 Application > 805.1.3 Insulating Boards
603.1.3 Types of Construction, Electrical
The use of electrical wiring methods
with combustible insulation, tubing, raceways and related
components shall be permitted where installed ...
2015 Michigan Building Code > 6 Types of Construction > 603 Combustible Material in Types I and II Construction > 603.1 Allowable Materials > 603.1.3 Electrical
720.5 Fire and Smoke Protection Features, Roof Insulation
The use of combustible roof insulation
not complying with Sections 720.2 and 720.3 shall be
permitted in any type of construction provided ...
2015 Michigan Building Code > 7 Fire and Smoke Protection Features > 720 Thermal-And Sound-Insulating Materials > 720.5 Roof Insulation
718.5 Fire and Smoke Protection Features, Combustible Materials in Concealed Spaces in Type I or II Construction
with the International
Mechanical Code and the International Plumbing
Code.
Combustible insulation and covering on pipe and
tubing, installed in concealed ...
2015 Michigan Building Code > 7 Fire and Smoke Protection Features > 718 Concealed Spaces > 718.5 Combustible Materials in Concealed Spaces in Type I or II Construction