Section 1109 Combined Sanitary and Storm System

Go To Full Code Chapter
1109.1 Size of Combined Drains and Sewers
The size of a combination sanitary and storm drain or sewer shall be computed in accordance with the method in Section 1106.3. The fixture units shall be converted into an equivalent projected roof or paved area. Where the total fixture load on the combined drain is less than or equal to 256 fixture units, the equivalent drainage area in horizontal projection shall be taken as 4,000 square feet (372 m2). Where the total fixture load exceeds 256 fixture units, each additional fixture unit shall be considered the equivalent of 15.6 square feet (1.5 m2) of drainage area. These values are based on a rainfall rate of 1 inch (25 mm) per hour.

Related Code Sections

Section 1109 Storm Drainage, Combined Sanitary and Storm System
The size of a combination sanitary and storm drain or sewer shall be computed in accordance with the method in Section 1106.3. The fixture units ...
1104.2 Storm Drainage, Combining Storm With Sanitary Drainage
The sanitary and storm drainage systems of a structure shall be entirely separate except where combined sewer systems are utilized. Where a combined ...
703.3 Sanitary Drainage, Sanitary and Storm Sewers
Where separate systems of sanitary drainage and storm drainage are installed in the same property, the sanitary and storm building sewers or drains ...
1101.9 Storm Drainage, Backwater Valves
Storm drainage systems shall be provided with backwater valves as required for sanitary drainage systems in accordance with Section 715 ...