• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1620.2.6 Collector Elements

NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.2 Structural Component Design and Detailing (For Use in the Simplified Analysis Procedure of Section 1617.5) > 1620.2.6 Collector Elements
JUMP TO FULL CODE CHAPTER
Collector elements shall be provided that are capable of transferring the seismic forces originating in other portions of the structure to the element providing the resistance to those forces. Collector elements, splices and their connections to resisting elements shall have the design strength to resist the special load combinations of Section 1605.4.

Exception: In structures or portions thereof braced entirely by light-framed shear walls, collector elements, splices and connections to resisting elements need only have the strength to resist the load combinations of Section 1605.2 or 1605.3.

Related Code Sections


1620.2.6 Structural Design, Collector Elements
Collector elements shall be provided that are capable of transferring the seismic forces originating in other portions of the structure ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.2 Structural Component Design and Detailing (For Use in the Simplified Analysis Procedure of Section 1617.5) > 1620.2.6 Collector Elements
18.12.3.1 Earthquake-Resistant Structures,
All diaphragms and their connections shall be designed and detailed to provide for transfer of forces to collector elements and to the vertical ...
Building Code Requirements for Structural Concrete of New York City > 18 Earthquake-Resistant Structures > 18.12 Diaphragms and Trusses > 18.12.3 Seismic Load Path > 18.12.3.1
12.5.4 Diaphragms, Collectors
Collectors shall extend from the vertical elements of the lateral-force-resisting system across all or part of the diaphragm depth as required ...
Building Code Requirements for Structural Concrete of New York City > 12 Diaphragms > 12.5 Design Strength > 12.5.4 Collectors
18.12.7.6 Earthquake-Resistant Structures,
Longitudinal reinforcement detailing for collector elements at splices and anchorage zones shall satisfy (a) or (b): (a) Center-to-center spacing ...
Building Code Requirements for Structural Concrete of New York City > 18 Earthquake-Resistant Structures > 18.12 Diaphragms and Trusses > 18.12.7 Reinforcement > 18.12.7.6
12.5.4.3 Diaphragms,
Where a collector is designed to transfer forces to a vertical element, collector reinforcement shall extend along the vertical element at least ...
Building Code Requirements for Structural Concrete of New York City > 12 Diaphragms > 12.5 Design Strength > 12.5.4 Collectors > 12.5.4.3
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING