• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1705.2.2 Cold-Formed Steel Deck

Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.2 Steel Construction > 1705.2.2 Cold-Formed Steel Deck
JUMP TO FULL CODE CHAPTER
Special inspections and qualification of welding special inspectors for cold-formed steel floor and roof deck shall be in accordance with the quality assurance inspection requirements of SDI QA/QC.

Related Code Sections


1705.2.2 Special Inspections and Tests, Cold-Formed Steel Deck
Special inspections and qualification of welding special inspectors for cold-formed steel floor and roof deck shall be in accordance ...
Building Code 2021 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.2 Steel Construction > 1705.2.2 Cold-Formed Steel Deck
1705.2.2 Special Inspections and Tests, Cold-Formed Steel Deck
Special inspections and qualification of welding special inspectors for cold-formed steel floor and roof deck shall be in accordance ...
Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.2 Steel Construction > 1705.2.2 Cold-Formed Steel Deck
2210.1.1.2 Steel, Steel Roof Deck
Steel roof decks shall be permitted to be designed and constructed in accordance with ANSI/SDI-RD1.0 ...
Building Code 2021 of Illinois > 22 Steel > 2210 Cold-Formed Steel > 2210.1 General > 2210.1.1 Steel Decks > 2210.1.1.2 Steel Roof Deck
2210.1.1.2 Steel, Steel Roof Deck
Steel roof decks shall be permitted to be designed and constructed in accordance with ANSI/SDI-RD1.0 ...
Building Code 2018 of Illinois > 22 Steel > 2210 Cold-Formed Steel > 2210.1 General > 2210.1.1 Steel Decks > 2210.1.1.2 Steel Roof Deck
2210.1.1 Steel, Steel Decks
The design and construction of cold-formed steel decks shall be in accordance with this section ...
Building Code 2018 of Illinois > 22 Steel > 2210 Cold-Formed Steel > 2210.1 General > 2210.1.1 Steel Decks
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING