Section 2210 Cold-Formed Steel

Go To Full Code Chapter
2210.1 General
The design of cold-formed carbon and low-alloy steel structural members shall be in accordance with AISI S100. The design of cold-formed stainless-steel structural members shall be in accordance with ASCE 8. Cold-formed steel light-frame construction shall comply with Section 2211. Where required, the seismic design of cold-formed steel structures shall be in accordance with the additional provisions of Section 2210.2.
2210.1.1 Steel Decks
The design and construction of cold-formed steel decks shall be in accordance with this section.
2210.1.1.1 Noncomposite Steel Floor Decks
Noncomposite steel floor decks shall be permitted to be designed and constructed in accordance with ANSI/SDI-NC1.0.
2210.1.1.2 Steel Roof Deck
Steel roof decks shall be permitted to be designed and constructed in accordance with ANSI/SDI-RD1.0.
2210.1.1.3 Composite Slabs on Steel Decks
Composite slabs of concrete and steel deck shall be permitted to be designed and constructed in accordance with SDI-C.
2210.2 Seismic Requirements for Cold-Formed Steel Structures
Where a response modification coefficient, R, in accordance with ASCE 7, Table 12.2-1, is used for the design of cold-formed steel structures, the structures shall be designed and detailed in accordance with the requirements of AISI S100, ASCE 8, or, for cold-formed steel special-bolted moment frames, AISI S400.

Related Code Sections

Section 2210 Steel, Cold-Formed Steel
The design of cold-formed carbon and low-alloy steel structural members shall be in accordance with AISI S100. The design of cold-formed stainless ...
Section 2210 Steel, Cold-Formed Steel
The design of cold-formed carbon and low-alloy steel structural members shall be in accordance with AISI S100. The design of cold-formed stainless ...
1705.2.2 Special Inspections and Tests, Cold-Formed Steel Deck
Special inspections and qualification of welding special inspectors for cold-formed steel floor and roof deck shall be in accordance with the quality ...
1705.2.2 Special Inspections and Tests, Cold-Formed Steel Deck
Special inspections and qualification of welding special inspectors for cold-formed steel floor and roof deck shall be in accordance with the quality ...
Section 2211 Steel, Cold-Formed Steel Light-Frame Construction
For cold-formed steel light-frame construction, the design and installation of the following structural framing systems, including their members ...