• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

307.6 Coke-Fueled Salamanders

NYC Fire Code 2014 > 3 General Precautions Against Fire > 307 Open Fires > 307.6 Coke-Fueled Salamanders
JUMP TO FULL CODE CHAPTER
Coke and coke-fueled salamanders may be stored, handled and used for construction-related curing and drying at construction sites in accordance with this section and the rules.

307.6.1 Supervision

The handling and use of coke and coke-fueled salamanders at construction sites, including the extinguishment of the coke, shall be under the personal supervision of a certificate of fitness holder. A certificate of fitness holder may not supervise the handling or use of more than fifty coke-fueled salamanders, or the handling or use of coke or coke-fueled salamanders that are located on more than one floor. The storage of coke and coke-fueled salamanders at construction sites shall be under the general supervision of a certificate of fitness holder.

Related Code Sections


502.1 Exhaust Systems, General
, tanks, furnaces, forges, salamanders and other appliances, equipment and processes in such areas produce or throw off dust or particles sufficiently ...
NYC Mechanical Code 2008 > 5 Exhaust Systems > 502 Required Systems > 502.1 General
502.1 Exhaust Systems, General
, tanks, furnaces, forges, salamanders and other appliances, equipment and processes in such areas produce or throw off dust or particles sufficiently ...
NYC Mechanical Code 2014 > 5 Exhaust Systems > 502 Required Systems > 502.1 General
101.2.5 Administration, Other Fuels
The requirements for the design, installation, maintenance, alteration and inspection of mechanical systems operating with fuels other than fuel gas ...
NYC Fuel Gas Code 2008 > 1 Administration > 101 General > 101.2 Scope > 101.2.5 Other Fuels
101.2.5 Administration, Other Fuels
The requirements for the design, installation, maintenance, alteration and inspection of mechanical systems operating with fuels other than fuel gas ...
NYC Fuel Gas Code 2014 > 1 Administration > 101 General > 101.2 Scope > 101.2.5 Other Fuels
1301.3 Fuel-Oil Piping and Storage, Fuel Type
An appliance shall be designed for use with the type of fuel to which it will be connected. Such appliance shall not be converted from the fuel ...
NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1301 General > 1301.3 Fuel Type
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE