• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

505.5 Coextruded Composite ABS Pipe and Joints

Private Sewage Disposal Code 2009 > 5 Materials > 505 Pipe, Joints and Connections > 505.5 Coextruded Composite ABS Pipe and Joints
JUMP TO FULL CODE CHAPTER
Joints between coextruded composite pipe with an ABS outer layer or ABS fittings shall comply with Sections 505.5.1 and 505.5.2.

505.5.1 Mechanical Joints

Mechanical joints on drainage pipe shall be made with an elastomeric seal conforming to ASTM C 1173, ASTM D 3212, or CSA B 602. Mechanical joints shall not be installed in above-ground systems, except as otherwise approved. Joints shall be installed in accordance with the manufacturer's installation instructions.

505.5.2 Solvent Cementing

Joint surfaces shall be clean and free from moisture. Solvent cement conforming to ASTM D 2235 or CSA B 181.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet. Joints shall be made in accordance with ASTM D 2235, ASTM D 2661, ASTM F 628 or CSA B181.1. Solvent cement joints shall be permitted above or below ground.

Related Code Sections


505.5 Materials, Coextruded Composite ABS Pipe and Joints
Joints between coextruded composite pipe with an ABS outer layer or ABS fittings shall comply with Sections 505.5.1 and 505.5.2 ...
Private Sewage Disposal Code 2015 > 5 Materials > 505 Pipe, Joints and Connections > 505.5 Coextruded Composite ABS Pipe and Joints
505.5 Materials, Coextruded Composite ABS Pipe and Joints
Joints between coextruded composite pipe with an ABS outer layer or ABS fittings shall comply with Sections 505.5.1 and 505.5.2 ...
Private Sewage Disposal Code 2012 > 5 Materials > 505 Pipe, Joints and Connections > 505.5 Coextruded Composite ABS Pipe and Joints
505.5 Materials, Coextruded Composite ABS Pipe and Joints
Joints between coextruded composite pipe with an ABS outer layer or ABS fittings shall comply with Sections 505.5.1 and 505.5.2 ...
Private Sewage Disposal Code 2009 > 5 Materials > 505 Pipe, Joints and Connections > 505.5 Coextruded Composite ABS Pipe and Joints
505.5.2 Materials, Solvent Cementing
Joint surfaces shall be clean and free from moisture. Solvent cement conforming to ASTM D 2235 or CSA B 181.1 shall be applied to all joint surfaces ...
Private Sewage Disposal Code 2012 > 5 Materials > 505 Pipe, Joints and Connections > 505.5 Coextruded Composite ABS Pipe and Joints > 505.5.2 Solvent Cementing
705.7 Sanitary Drainage, Coextruded Composite ABS Pipe, Joints
Joints between coextruded composite pipe with an ABS outer layer or ABS fittings shall comply with Sections 705.7.1 and 705.7.2 ...
Plumbing Code 2009 > 7 Sanitary Drainage > 705 Joints > 705.7 Coextruded Composite ABS Pipe, Joints
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE