• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1907.4.1 Coatings

NYC Building Code 2014 > 19 Concrete > 1907 Details of Reinforcement > 1907.4 Surface Conditions of Reinforcement > 1907.4.1 Coatings
JUMP TO FULL CODE CHAPTER
At the time concrete is placed, reinforcement shall be free from mud, oil or other nonmetallic coatings that decrease bond. Zinc and epoxy-coating of steel reinforcement in accordance with ACI 318, Sections 3.5.3.8, 3.5.3.9, and 3.5.3.10 shall be permitted.

Related Code Sections


1907.4.1 Concrete, Coatings
At the time concrete is placed, reinforcement shall be free from mud, oil or other nonmetallic coatings that decrease bond. Epoxy coatings of steel ...
NYC Building Code 2008 > 19 Concrete > 1907 Details of Reinforcement > 1907.4 Surface Conditions of Reinforcement > 1907.4.1 Coatings
1907.4.1 Concrete, Coatings
At the time concrete is placed, reinforcement shall be free from mud, oil or other nonmetallic coatings that decrease bond. Zinc and epoxy-coating ...
NYC Building Code 2014 > 19 Concrete > 1907 Details of Reinforcement > 1907.4 Surface Conditions of Reinforcement > 1907.4.1 Coatings
§27-349 Fire Protection Construction Requirements, Coatings
Coatings applied in the field by brush or spray shall not be used as flame-spread retardants except on existing surfaces of buildings existing ...
NYC 1968 Code (Vol I) > 5 Fire Protection Construction Requirements > 5 Prevention of Interior Fire Spread > §27-349 Coatings
2103.11.7.2 Masonry, Epoxy Coatings
Carbon steel accessories shall be epoxy-coated as follows:   1. For joint reinforcement, comply with the requirements of ASTM A 884 Class ...
NYC Building Code 2008 > 21 Masonry > 2103 Masonry Construction Materials > 2103.11 Metal Reinforcement and Accessories > 2103.11.7 Corrosion Protection > 2103.11.7.2 Epoxy Coatings
2512.9 Gypsum Board and Plaster, Finish Coats
Cement plaster finish coats shall be applied over base coats that have been in place for the time periods set forth in ASTM C 926. The third ...
NYC Building Code 2008 > 25 Gypsum Board and Plaster > 2512 Exterior Plaster > 2512.9 Finish Coats
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE