• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1008.1.9.5.1 Closet and Bathroom Doors in Certain Group R Occupancies

NYC Building Code 2014 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.9 Door Operations > 1008.1.9.5 Unlatching > 1008.1.9.5.1 Closet and Bathroom Doors in Certain Group R Occupancies
JUMP TO FULL CODE CHAPTER
In community residences or intermediate-care facilities classified as Group R-1, R-2 or R-3 occupancies pursuant to Section 308.2.2, Exception 1, 2 or 3, within such facilities, closet doors that latch in the closed position shall be openable from inside the closet, and bathroom doors that latch in the closed position shall be capable of being unlocked from the ingress side.

Related Code Sections


1008.1.9.5.1 Means of Egress, Closet and Bathroom Doors in Certain Group R Occupancies
In community residences or intermediate-care facilities classified as Group R-1, R-2 or R-3 occupancies pursuant to Section 308.2.2, Exception 1, 2 ...
NYC Building Code 2014 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.9 Door Operations > 1008.1.9.5 Unlatching > 1008.1.9.5.1 Closet and Bathroom Doors in Certain Group R Occupancies
Section P102 R-2 Occupancy Toilet and Bathing Facilities Requirements, Toilet and Bathing Facilities
, including those within a toilet and bathing facility accessed through a private office by a single occupant, shall comply with Section 606 of ICC A117.1 ...
NYC Building Code 2008 > P R-2 Occupancy Toilet and Bathing Facilities Requirements > P102 Toilet and Bathing Facilities
310.4 General Regulations, Water Closet Compartment
to ensure privacy. Exceptions: Water closet compartments shall not be required in a single-occupant toilet room with a lockable door. Toilet ...
NYC Plumbing Code 2014 > 3 General Regulations > 310 Washroom and Toilet Room Requirements > 310.4 Water Closet Compartment
1107.2.1 Accessibility, Type B Unit Doors and Doorways in R-2 Occupancy
swing of the door will not obstruct the maneuvering clearances required at the door or doorway. Flex-closet. Where front approach, pull side ...
NYC Building Code 2008 > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.2 Design > 1107.2.1 Type B Unit Doors and Doorways in R-2 Occupancy
§27-759 Light, Heat, Ventilation and Noise Control, Bathrooms and Toilet Rooms
the net free area of the ventilation sources be less than one and one-half square feet except that in occupancy groups H-1 and H-2, provided ...
NYC 1968 Code (Vol I) > 12 Light, Heat, Ventilation and Noise Control > 8 Ventilation of Special Spaces > §27-759 Bathrooms and Toilet Rooms
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE