• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

509.4 Clock

Section 3109 of the 2015 WSBC > 5 Public Spas and Public Exercise Spas > 509 Safety Features > 509.4 Clock
JUMP TO FULL CODE CHAPTER
Public facilities shall have a clock that is visible to spa users.

Related Code Sections


509.4 Public Spas and Public Exercise Spas, Clock
Public facilities shall have a clock that is visible to spa users ...
Section 3109 of the 2015 WSBC > 5 Public Spas and Public Exercise Spas > 509 Safety Features > 509.4 Clock
E109.2.8 Supplementary Accessibility Requirements, Clocks
Where clocks are provided for use by the general public, the clock face shall be uncluttered so that its elements are clearly visible. Hands ...
2015 Washington State Building Code > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations > E109.2 New Construction > E109.2.8 Clocks
E109.2.8 Supplementary Accessibility Requirements, Clocks
Where clocks are provided for use by the general public, the clock face shall be uncluttered so that its elements are clearly visible. Hands ...
2018 Washington State Building Code > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations > E109.2 New Construction > E109.2.8 Clocks
E110.4 Supplementary Accessibility Requirements, Clocks
Where clocks are provided for use by the general public, the clock face shall be uncluttered so that its elements are clearly visible. Hands ...
2015 Washington State Building Code > E Supplementary Accessibility Requirements > E110 Airports > E110.4 Clocks
E110.4 Supplementary Accessibility Requirements, Clocks
Where clocks are provided for use by the general public, the clock face shall be uncluttered so that its elements are clearly visible. Hands ...
2018 Washington State Building Code > E Supplementary Accessibility Requirements > E110 Airports > E110.4 Clocks
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE