§40-38 Clearances From Combustible Materials
JUMP TO FULL CODE CHAPTER
(a) Space heaters and water heaters approved by the American Gas Association Laboratories, shall have clearance from combustible materials in accordance with the terms of their approval.
(b) Gas-fueled space and water heaters shall be installed also in conformity with any applicable requirements of specification Z21-30 of 1954 of the American Standards Association, except where these rules otherwise provide.
(c) Vent connectors and vent and outlet pipes shall be installed so as to provide a minimum clearance of three inches on all sides from combustible material. Vent and outlet pipes shall not pass through a floor. Where a vent or outlet pipe passes through a partition or roof constructed wholly or in part of combustible material, a ventilated metal thimble not less than six inches larger in diameter than the pipe shall be provided. Any material used to fill the space between the vent pipe and the thimble shall be incombustible.
Related Code Sections
611.3 Specific Appliances, Clearance From Combustible Materials
Nonrecirculating direct-fired industrial air heaters shall be installed with a clearance from combustible materials of not less than that shown ...
NYC Fuel Gas Code 2014 > 6 Specific Appliances > 611 Nonrecirculating Direct-Fired Industrial Air Heaters > 611.3 Clearance From Combustible Materials
611.3 Specific Appliances, Clearance From Combustible Materials
Nonrecirculating direct-fired industrial air heaters shall be installed with a clearance from combustible materials of not less than that shown ...
NYC Fuel Gas Code 2008 > 6 Specific Appliances > 611 Nonrecirculating Direct-Fired Industrial Air Heaters > 611.3 Clearance From Combustible Materials
612.4 Specific Appliances, Clearance From Combustible Materials
Direct-fired industrial air heaters shall be installed with a clearance from combustible material of not less than that shown on the label ...
NYC Fuel Gas Code 2014 > 6 Specific Appliances > 612 Recirculating Direct-Fired Industrial Air Heaters > 612.4 Clearance From Combustible Materials
612.4 Specific Appliances, Clearance From Combustible Materials
Direct-fired industrial air heaters shall be installed with a clearance from combustible material of not less than that shown on the label ...
NYC Fuel Gas Code 2008 > 6 Specific Appliances > 612 Recirculating Direct-Fired Industrial Air Heaters > 612.4 Clearance From Combustible Materials
912.2 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Clearances
Heaters shall be installed with clearances from combustible material in accordance with the manufacturer's installation instructions ...
NYC Mechanical Code 2008 > 9 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 912 Infrared Radiant Heaters > 912.2 Clearances