1003.11.2.4.4 Clearance Overlap
JUMP TO FULL CODE CHAPTER
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, paper dispensers, coat hooks, shelves, accessible routes, clear floor space required at other fixtures, and the wheelchair turning space. No other fixtures or obstructions shall be located within the required water closet clearance.
Exception: A lavatory measuring 24 inches (610 mm) maximum in depth and complying with Section 1003.11.2.2 shall be permitted on the rear wall 18 inches (455 mm) minimum from the centerline of the water closet to the side edge of the lavatory where the clearance at the water closet is 66 inches (1675 mm) minimum measured perpendicular from the rear wall.
Related Code Sections
1003.11.2.4.4 Dwelling Units and Sleeping Units, Clearance Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, paper dispensers, coat hooks ...
Minnesota Accessibility Code 2015 > 10 Dwelling Units and Sleeping Units > 1003 Type A Units > 1003.11 Toilet and Bathing Facilities > 1003.11.2 General > 1003.11.2.4 Water Closet > 1003.11.2.4.4 Clearance Overlap
1004.11.3.1.2.2.4 Dwelling Units and Sleeping Units, Clearance Overlap
A vanity or other obstruction 24 inches (610 mm) maximum in depth, measured perpendicular from the rear wall, shall be permitted to overlap ...
Minnesota Accessibility Code 2015 > 10 Dwelling Units and Sleeping Units > 1004 Type B Units > 1004.11 Toilet and Bathing Facilities > 1004.11.3 Toilet and Bathing Areas > 1004.11.3.1 Option A > 1004.11.3.1.2 Water Closet > 1004.11.3.1.2.2 Clearance > 1004.11.3.1.2.2.4 Clearance Overlap
604.3.3 Plumbing Elements and Facilities, Clearance Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, toilet paper and sanitary seat ...
Minnesota Accessibility Code 2015 > 6 Plumbing Elements and Facilities > 604 Water Closets and Toilet Compartments > 604.3 Clearance > 604.3.3 Clearance Overlap
301.2 Building Blocks, Overlap
Unless otherwise specified, clear floor spaces, clearances at fixtures, maneuvering clearances at doors, and turning spaces shall be permitted ...
1102.4.4 Recreational Facilities, Clearances
to overlap required clearances. Wheelchair spaces shall be permitted to be mechanically or manually repositioned. Wheelchair spaces shall ...
Minnesota Accessibility Code 2015 > 11 Recreational Facilities > 1102 Amusement Rides > 1102.4 Wheelchair Spaces in Amusement Rides > 1102.4.4 Clearances