11B-406.5.9 Clear Space at Diagonal Curb Ramps
JUMP TO FULL CODE CHAPTER
The bottom of diagonal curb ramps shall have a clear space 48 inches (1219 mm) minimum outside active traffic lanes of the roadway. Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1219 mm) minimum clear space within the markings.
Related Code Sections
11B-406.5.9 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Clear Space at Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1219 mm) minimum outside active traffic lanes of the roadway. Diagonal curb ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-406 Curb Ramps, Blended Transitions and Islands > 11B-406.5 Common Requirements > 11B-406.5.9 Clear Space at Diagonal Curb Ramps
1112A.4 Housing Accessibility, Diagonal Curb Ramps
flow. The bottom of diagonal curb ramps shall have a 48-inch (1219 mm) minimum clear space as shown in Figures 11A-3A through 11A-3M. If diagonal curb ...
Los Angeles Building Code > 11A Housing Accessibility > 1112A Curb Ramps on Accessible Routes > 1112A.4 Diagonal Curb Ramps
11B-705.1.2.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Curb Ramps
, street or highway. Exception: On parallel curb ramps, detectable warnings shall be placed on the turning space at the flush transition between ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-705 Detectable Warnings and Detectable Directional Texture > 11B-705.1 Detectable Warnings > 11B-705.1.2 Locations > 11B-705.1.2.2 Curb Ramps
11B-247.1.2.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Curb Ramps
Curb ramps shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.2 ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-247 Detectable Warnings and Detectable Directional Texture > 11B-247.1 Detectable Warnings > 11B-247.1.2 Where Required > 11B-247.1.2.2 Curb Ramps
11B-405 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Ramps
The clear width of a ramp run shall be 48 inches (1219 mm) minimum. Exceptions ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-405 Ramps