1009.2.3 Clear Deck Space
JUMP TO FULL CODE CHAPTER
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm) wide minimum and shall extend forward 48 inches (1220 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat. The clear deck space shall have a slope not steeper than 1:48.
![]() |
Related Code Sections
1009.2.3 Recreation Facilities, Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm ...
2010 ADA Standards > 10 Recreation Facilities > 1009 Swimming Pools, Wading Pools, and Spas > 1009.2 Pool Lifts > 1009.2.3 Clear Deck Space
1009.2 Recreation Facilities, Pool Lifts
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches ...
2010 ADA Standards > 10 Recreation Facilities > 1009 Swimming Pools, Wading Pools, and Spas > 1009.2 Pool Lifts
1009.5 Recreation Facilities, Transfer Systems
platform. The side of the transfer platform serving the transfer space shall be unobstructed. Figure 1009.5.2 Clear Deck Space at Transfer ...
2010 ADA Standards > 10 Recreation Facilities > 1009 Swimming Pools, Wading Pools, and Spas > 1009.5 Transfer Systems
1005 Recreation Facilities, Fishing Piers and Platforms
design, permitting individuals using wheelchairs or other mobility devices to pull into a clear space and move beyond the face of the railing. In ...
1005.3 Recreation Facilities, Edge Protection
using wheelchairs or other mobility devices to pull into a clear space and move beyond the face of the railing. In such a design, curbs or barriers ...
2010 ADA Standards > 10 Recreation Facilities > 1005 Fishing Piers and Platforms > 1005.3 Edge Protection